New potential reference materials for in-situ microscale Ag isotope analysis by fsLA-MC-ICP-MS.
Deyi Peng, Zhian Bao, Peng Liang, Kaiyun Chen, Honglin Yuan
State Key Laboratory of Continental Evolution and Early Life, Department of Geology, Northwest University, Xi'an, 710069, China. · State Key Laboratory of Continental Evolution and Early Life, Department of Geology, Northwest University, Xi'an, 710069, China. Electronic address: geobza@126.com.
Key points
From the paper's conclusion- These candidate reference materials are suitable as bracketing standards and quality control references for laser ablation Ag isotope analysis.
Abstract
Silver isotopes are emerging geochemical tracers with increasing applications across earth sciences, environmental sciences, and archaeometry. Conventional Ag isotope analyses relying on chemical digestion of samples lack spatial resolution and are destructive, restricting their use for samples with micro-scale isotopic heterogeneity or precious archaeological artifacts. Laser ablation (LA)-MC-ICP-MS provides a minimally destructive alternative with high spatial resolution, but its analytical accuracy depends critically on suitable matrix-matched reference materials. Natural minerals with homogeneous Ag isotopic compositions are ideal candidate reference materials, yet they are scarce. To overcome this limitation, we developed synthetic gold- and silver-matrix materials as viable alternative calibrants for in-situ Ag isotope analysis. In addition, this study establishes a suite of natural reference materials, including native gold (Au1, Au2, and Au3), native silver (NAg), proustite (Pro1, Pro2, and Pro3), and argentite (Arg). In-situ Ag isotopic analyses demonstrate that all proposed candidate materials are isotopically homogeneous, with long-term analytical precision better than 0.08‰ (two standard deviations, 2SD). Both synthetic and natural reference materials serve as effective calibrants for LA-MC-ICP-MS, yielding Ag isotopic ratios consistent with solution-based values, indicating negligible matrix effects. These candidate reference materials are suitable as bracketing standards and quality control references for laser ablation Ag isotope analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Determination of the isotopic composition of silver by MC-ICP-MS using an improved full gravimetric isotope mixture method.Analytical and bioanalytical chemistry · 2026
- Advances in (LA)-ICP-MS techniques and applications for the in elemental analysis the field of cultural heritage: A reviewTalanta · 2026
- In-situ laser ablation MC-ICP-MS of lead white in paintings.NPJ heritage science · 2026
- Calibration-Free Analysis of Li Isotope Ratios Using Laser Ablation and Laser Absorption SpectroscopyAnalytical Chemistry · 2026
- Synthetic Cassiterite Reference Material for High-Precision In Situ Sn Isotope Analysis by LA-MC-ICP-MS.Analytical chemistry · 2026
- Method Development and Validation for Simultaneous In Situ Fe Isotope and Multi-Element Analysis by LASS MC-ICP-MS/ICP-ToF-MS.Analytical chemistry · 2026