A Multi-Standard Linear Regression Calibration for SIMS Sulfur Isotope Analysis of Pyrrhotite
Fu-De Zhao, Xiao-Yan Liu, Lei Chen, Qiu-Li Li, Ning-Yue Sun, Xian-Hua Li
Key points
From the paper's conclusion- This study presents a multi-standard linear regression calibration protocol to mitigate the matrix effects and retrieve reliable δ34S values from pyrrhotite.
Abstract
Instrumental mass fractionation (IMF) occurring during secondary ion mass spectrometry (SIMS) sulfur isotope analysis in geological samples has been evaluated. Given the non-stoichiometric nature and structural variability of pyrrhotite (Fe1-xS), we investigated the role of its chemical composition and crystal structure (matrix effects) on IMF during SIMS sulfur isotope analysis. This study presents a multi-standard linear regression calibration protocol to mitigate the matrix effects and retrieve reliable δ34S values from pyrrhotite. This approach avoids the need for strict compositional and structural matching between pyrrhotite reference materials (RMs) and unknowns. The results demonstrate that the corrected δ34S value of Po-10, treated as an unknown pyrrhotite RM, is 5.97 ± 0.39‰ (2SD, n = 19), in close agreement with its recommended value of 6.0 ± 0.1‰ (2SD), validating the reliability of the protocol. This robust and reproducible protocol is expected to facilitate broader application of in situ sulfur isotope measurements of pyrrhotite to trace the formation processes of Fe sulfides occurring in magmatic–hydrothermal ore deposits and meteorites.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of Arsenopyrite Reference Materials (Sacra and Niko) for In situ Multiple Sulfur Isotope MeasurementGeostandards and Geoanalytical Research · 2026
- A Novel Strategy for Synthesizing Matrix-Matched Microanalysis Reference Materials via Hydrothermal Precursors and Ultrahigh-Pressure SinteringAnalytical Chemistry · 2026
- Achieving ppm-Level Precision and Accuracy in Triple Silicon Isotope Measurements by Gas Source Isotope Ratio Mass Spectrometry.Analytical chemistry · 2026
- In Situ Sulphur Isotopic Analysis of Alunite by LA‐MC‐ICP‐MSActa Geologica Sinica - English Edition · 2026
- Determination of the isotopic composition of silver by MC-ICP-MS using an improved full gravimetric isotope mixture method.Analytical and bioanalytical chemistry · 2026
- Afghanite: A New Silicate‐Matrix Reference Material for In Situ Halogen and Sulfur MicroanalysisGeostandards and Geoanalytical Research · 2026