Raman-Based Internal Standardization for Quantitative LA-ICP-MS Analysis of Individual Fluid Inclusions.
Qin-Di Wei, Zheng-Jie Qiu, Liang-Liang Huang, Qi Li, Yong-Sheng Yao, Xue-Yin Yuan, Ting-Guang Lan, Hong-Rui Fan
Institutional Center for Shared Technologies and Facilities, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing100029, China. · State Key Laboratory of Lithospheric and Environmental Coevolution, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing100029, China.
Key points
From the paper's conclusion- Here, we introduce an integrated Raman microspectroscopy and LA-ICP-MS workflow that overcomes this limitation by converting the Raman-derived concentration of boric acid (B(OH)3) to an equivalent elemental B concentration for internal standardization.
Abstract
A central challenge in quantitative laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) analysis of individual fluid inclusions is the lack of a directly measurable internal standard. Current approaches typically rely on Na concentrations inferred from microthermometric NaCl-equivalent salinity, yet in multicomponent fluids this approach can introduce considerable bias because the effects of non-chloride solutes on phase-transition (e.g., ice melting) temperatures remain poorly constrained. Here, we introduce an integrated Raman microspectroscopy and LA-ICP-MS workflow that overcomes this limitation by converting the Raman-derived concentration of boric acid (B(OH)3) to an equivalent elemental B concentration for internal standardization. Our results show that the ν1(BO3)/ν2(H-O-H) area ratio is markedly less sensitive to salinity than conventional normalization to the O-H stretching envelope. In quartz-hosted synthetic fluid inclusions, Aν1(BO3)/Aν2(H-O-H) follows a single linear calibration for 10 and 20 wt % NaCl solutions (y = (8.68 ×10-5)x, R2 = 0.9995), enabling direct determination of elemental B concentrations without salinity-specific calibration. Ab initio molecular dynamics Raman simulations support the molecular basis of this metric. Using Raman-derived B concentrations as the internal standard yields mean signed deviations of -11.9 to 6.4% and mean absolute relative deviations of 1.9-11.9% for Li, Na, Mg, K, Rb, Sr, and Cs, whereas conventional microthermometry-based Na standardization produces systematic positive deviations of 8.5-38.0%. This strategy improves quantification of B-bearing fluid inclusions and establishes a general analytical framework for quantitative multielement analysis of aqueous systems containing Raman-active dissolved species.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- New potential reference materials for in-situ microscale Ag isotope analysis by fsLA-MC-ICP-MS.Talanta · 2026
- Mathematical Framework for the Effects of Sample Absorption on Raman Intensity for Quantification and Detection Thresholds of Minerals in Two-Component Geological Mixtures.Analytical chemistry · 2026
- A novel approach for monitoring the spatial distribution and quantitative analysis of micronutrients in plant tissues using laser ablation ICP-MS imaging.Analytical and bioanalytical chemistry · 2026
- JCp-1-NP: New and compiled LA-ICP-MS elemental compositional data of the nano-powdered reference material.Scientific data · 2026
- Evaluating limits of detection for single-cell elemental bioimaging by LA-ICP-TOFMSTalanta · 2026
- Calibration-Free Analysis of Li Isotope Ratios Using Laser Ablation and Laser Absorption SpectroscopyAnalytical Chemistry · 2026