Highly Superficial Flexible Coil Array for 1.5T MRI: Diagnostic Quality Evaluation Compared to Conventional Technology.
Vicente Caruana Denia, Laura Perez-Sanchez, Enrique Hernandez-Zurita, Jose M Garcia-Santos, Margarita Martinez-Fernandez, Almudena Garcia-Geronimo, Antonio Martinez-Gonzalez, Juan D Sanchez-Heredia
Key points
From the paper's conclusion- The proposed flexible 1.5T coil array enhances superficial SNR and patient comfort without compromising diagnostic quality.
Abstract
OBJECTIVE: To assess the imaging performance, thermal behavior, and patient acceptance of a novel 3-channel flexible coil array for 1.5T MRI (64 MHz), compared to a conventional 16-channel flexible coil. METHODS: A lightweight array with three 60 mm copper loops and a compact 32×15 mm electronics board was developed, integrating tuning, matching, decoupling, RF filtering, and preamplification. Bench tests evaluated Q-factor ratio, SNR degradation under bending, phantom-based SNR, and thermal dissipation. Clinical evaluation involved hand imaging of 10 healthy volunteers (22.9 ± 0.3 years) using Cor-T1 and Ax-T2FS sequences in two positions (superman and supine). Image quality was rated by two radiologists across five tissue types using a 5-point Likert scale. Patient comfort and anxiety were assessed via post-scan questionnaires. RESULTS: In vitro tests showed a 1.6-fold SNR improvement for superficial regions (≤10 mm depth) and approximately 40% SNR loss under extreme bending, confirming robust decoupling and conformability. Radiologists reported significantly better image quality for Ax-T2FS with the flexible array, while Cor-T1 showed no significant difference. Patient comfort was markedly higher with the flexible array (85% vs. 45%), suggesting ergonomic advantages that may reduce motion artifacts. CONCLUSION: The proposed flexible 1.5T coil array enhances superficial SNR and patient comfort without compromising diagnostic quality. SIGNIFICANCE: High-density arrays of small coils can deliver clinical benefits at 1.5T, supporting their use for improved imaging in anatomically challenging regions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of a novel flexible, lightweight blanket-like torso coil in pediatric MRI at 1.5-T - initial experience.Pediatric radiology · 2026
- Evaluation of a modular flexible coil for thoracic outlet syndrome MRI at 3 T.Magma (New York, N.Y.) · 2026
- Diagnostic Performance of a Metasurface Coil Compared With a Commercial 12-Channel Coil for Knee MRI at 1.5 T.Journal of magnetic resonance imaging : JMRI · 2026
- Phantom imaging performance and initial in vivo feasibility of an anatomy-conforming dentomaxillofacial prototype coil for dental MRIBMC Medical Imaging · 2026
- Improved SNR and Image Quality of Pediatric MRI with a Shape Conforming High-Density Posterior Cushion Coil.Bioengineering (Basel, Switzerland) · 2026
- Impact of maternal positioning on maternal comfort and fetal magnetic resonance imaging quality in a 75-cm bore system.Journal of perinatal medicine · 2026