Biomechanical efficacy of wire fixation methods for oblique metacarpal shaft fractures
Yung‐Cheng Chiu, Tsung-Yu Ho, Chen-Wei Yeh, Ming-Tzu Tsai, Cheng-En Hsu, Jui‐Ting Hsu
China Medical University · Hungkuang University
Key points
From the paper's conclusion- The LBW&CW method provides superior fixation strength to that of the other 3 methods in the fixation of midshaft vertical oblique metacarpal fractures.
Abstract
BACKGROUND: Fractures of the metacarpal shaft are common. In treating stable metacarpal fractures, conservative treatment with splint immobilization yields favorable outcomes. Complex and unstable fractures typically require surgical intervention. The objective of this study was to determine the fixation capabilities of multiple combinations of K-wires and cerclage wiring in treating oblique metacarpal shaft fractures. METHODS: Vertical oblique metacarpal fractures at the midshaft of 28 artificial metacarpal bones (Sawbones, Vashon) were induced by using an electric saw. The fractured metacarpal bones were divided into 4 fixation treatment groups: Group 1 used 2 K-wires (2K), group 2 used 1 K-wire and a cerclage wire (1K&CW), group 3 used a vertical bone wire and a cerclage wire (VBW&CW), and group 4 used a lateral bone wire and a cerclage wire (LBW&CW). To measure maximum fracture force and bone stiffness, cantilever bending tests were conducted. The fixation capabilities of the 4 groups were compared using analysis of variance and Tukey test. RESULTS: Maximum fracture force in the LBW&CW group (mean ± standard deviation, 113.60 ± 8.66 N) considerably exceeded that in the VBW&CW group (66.51 ± 17.27 N) and that in the 1K&CW group (65.44 ± 16.59 N). The 2K group (36.10 ± 8.32 N) exhibited the weakest maximum fracture force. The ranking of the groups from highest to lowest by average stiffness was as follows: LBW&CW group (32.34 ± 4.62 N/mm), VBW&CW group (25.47 ± 5.96 N/mm), 1K&CW group (17.70 ± 6.27 N/mm), and 2K group (15.51 ± 2.48 N/mm). CONCLUSION: The LBW&CW method provides superior fixation strength to that of the other 3 methods in the fixation of midshaft vertical oblique metacarpal fractures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intramedullary K-Wire with Immediate Mobilisation versus Percutaneous Transverse K-Wire Fixation for Transverse Metacarpal Shaft Fractures.The journal of hand surgery Asian-Pacific volume · 2026
- Internal Fixation Bone Mass Index (IFBM) and Biomechanical Performance of Different Fixation Methods for Herscovici Type B and Type C Medial Malleolar Fractures.The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons · 2026
- Biomechanical evaluation of cerclage fixation constructs in a 3-dimensionally printed canine tibial long-oblique fracture model.American journal of veterinary research · 2026
- Fixation Strategies for Metacarpal Shaft Fractures: A Comparison of Plate-and-Screw, Intramedullary Screw, and Percutaneous Wire Techniques.The Journal of hand surgery · 2026
- Biomechanical comparison of modified tension band wiring using Kirschner wires with eyelets and conventional tension band wiring for olecranon fractures: A composite bone study.Clinical biomechanics (Bristol, Avon) · 2026
- Radiological outcomes of metacarpal fractures fixed with intramedullary headless compression screws compared to dorsal plates.Hand surgery & rehabilitation · 2026