Biomechanical evaluation of cerclage fixation constructs in a 3-dimensionally printed canine tibial long-oblique fracture model.
Jongmin Park, Jung-Moon Kim, Hwi-Yool Kim
Department of Veterinary Medicine, Graduate School, Konkuk University, Seoul, Republic of Korea. · Bon Animal Medical Center, Suwon, Republic of Korea.
Key points
From the paper's conclusion- PCCS demonstrated resistance to axial compression comparable to SSW fixation, whereas FW cerclage demonstrated the highest maximum failure load.
Abstract
OBJECTIVE: To compare the biomechanical performance of cerclage fixation constructs in a standardized 3-D-printed canine tibial long-oblique fracture model. METHODS: 3 fixation constructs-stainless steel wire cerclage (SSW), FiberWire cerclage (FW), and paraosseous clamp-cerclage stabilization (PCCS)-were compared in a standardized 3-D-printed canine tibial long-oblique fracture model. A standardized mid-diaphyseal long-oblique fracture was created in each specimen. Axial compression testing was performed until failure. Loads required to reach predefined displacement levels (1, 2, and 3 mm), maximum failure load, and failure mode were recorded. Data were analyzed using one-way ANOVA with the Tukey post hoc test. RESULTS: 21 tibial models (7/group) were evaluated. At all displacement levels, the FW group required significantly lower loads than both the SSW and PCCS groups, whereas no significant difference was observed between the SSW and PCCS groups. Mean loads at 1 mm displacement were 194.5 ± 32.2 N (SSW), 94.4 ± 21.0 N (FW), and 207.3 ± 64.0 N (PCCS). Maximum failure load was highest in the FW group (974.3 ± 77.0 N), followed by the PCCS group (879.0 ± 66.6 N) and SSW group (567.6 ± 63.2 N). CONCLUSIONS: PCCS demonstrated resistance to axial compression comparable to SSW fixation, whereas FW cerclage demonstrated the highest maximum failure load. CLINICAL RELEVANCE: These findings provide biomechanical information that may assist surgeons in selecting cerclage fixation methods for long-oblique tibial fractures in dogs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Two headless cannulated screws have a higher maximum failure load than screw-and-pin fixation at a 70° fracture angle in 3-dimensionally printed canine femoral neck models.American journal of veterinary research · 2026
- Cerclage Wire as an Affordable Alternative for Internal Fixation in Murine Critical Sized Defect Models.bioRxiv : the preprint server for biology · 2026
- Development and biomechanical study of a novel tibial external fixation device in synthetic tibial fracture models.Clinical biomechanics (Bristol, Avon) · 2026
- Dedicated Tibial Tuberosity Fixation Plates Provide Comparable Stiffness to Pin and Figure-of-eight Wire Constructs in Ex Vivo Stabilization of Laterally Transposed Tibial Crests.Veterinary and comparative orthopaedics and traumatology : V.C.O.T · 2026
- Fixation of proximal humeral Salter-Harris type 1 fractures in a 3-dimensionally printed skeletally immature canine bone model: a biomechanical assessment of fully threaded headless cannulated screws.American journal of veterinary research · 2026
- Biomechanical comparison of prophylactic fixation methods following excision of benign aggressive tumors of the femoral neck using composite bone models.Clinical biomechanics (Bristol, Avon) · 2026