Participant experience with the SpaceLabs 90227 ambulatory blood pressure monitor and SOMNOmedics ABPMpro device.
Josephine Soddano, Brandon Fernandez Sedano, Sumayya Shurovi, Michelle L David, Guixiao Ding, Fatma Dansoko, Joseph E Schwartz, Marwah Abdalla
Department of Medicine, Columbia University Irving Medical Center, New York.
Key points
From the paper's conclusion- We compared participant experience with a traditional oscillometric ABPM device and a compact cuff-integrated ABPM.
Abstract
Ambulatory blood pressure monitoring (ABPM) is recommended for confirming hypertension and assessing out-of-office blood pressure (BP). However, patient burden and device tolerability may limit broader implementation. We compared participant experience with a traditional oscillometric ABPM device and a compact cuff-integrated ABPM. The PRO-BP Study was a pilot randomized crossover study of 20 adults in New York City. Participants completed two 24-h ABPM periods over 7 days using the SpaceLabs 90227 and SOMNOmedics ABPMpro devices. After each period, participants rated comfort, pain, sleep interference, embarrassment, noise, skin irritation, and interference with daytime activities. Both devices achieved guideline-based recording-quality thresholds. Compared with SpaceLabs, ABPMpro was associated with greater comfort [median: 7.0 (interquartile range - IQR: 5.0-8.5) vs. 3.5 (IQR: 2.0-6.5); P = 0.026] and less pain [1.5 (0-3.5) vs. 5.0 (0.5-7.0); P = 0.022]. Other experience ratings did not differ significantly. Participant experience should be considered alongside recording quality when evaluating validated ambulatory BP monitoring technologies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Toward patient-centered blood pressure monitoring: first evaluation of a low-pressure and rapid oscillometric method for reducing cuff-related measurement burden.Hypertension research : official journal of the Japanese Society of Hypertension · 2026
- Validation study on cuffless ambulatory blood pressure monitoring method using bio-impedance, impedance cardiography and electrocardiography.European journal of applied physiology · 2026
- Toward patient-centered blood pressure monitoring: validation of a novel low-pressure and rapid oscillometric method according to the ISO 81060-2:2018/Amd1:2020/Amd2:2024 standard.Hypertension research : official journal of the Japanese Society of Hypertension · 2026
- The First Hour of Ambulatory Blood-Pressure Monitoring Mirrors the White-Coat Effect: A Population StudyJournal of Clinical Medicine · 2026
- Validation of a wrist-worn dual-sensor applanation tonometry device for blood pressure measurement under rest and stress conditionsEuropean Heart Journal · 2026
- Nocturnal Blood Pressure Dipping in Adults: A Comparison Between Cuffless and Ambulatory Blood Pressure Monitoring.American journal of hypertension · 2026