Hemodynamic Effects of Three Different Mechanical Circulatory Support Strategies in Isolated Acute Right Heart Failure.
Gábor Bari, Silvia Mariani, Maria Elena De Piero, Marc Dickstein, Jan Schreuder, Jan Schmitto, Michele Di Mauro, Bas van Bussel,
From the Clinic of Internal Medicine and Cardiac Center, Department of Cardiac Surgery, University of Szeged, Szeged, Hungary. · Maastricht University Medical Center, Cardio-Thoracic Surgery Department and Cardiovascular Research Institute Maastricht, Maastricht, the Netherlands.
Key points
From the paper's conclusion- We compared femoro-femoral VA ECMO, single-lumen cannula femoro-pulmonary artery (V-Pa), and double-lumen cannula right atrium-to-pulmonary artery (RA-Pa) support configurations in a swine model of ischemic aRVF-induced cardiogenic shock.
Abstract
Although acute right ventricular failure (aRVF) is commonly treated with venoarterial extracorporeal membrane oxygenation (VA ECMO), this approach may increase complications. We compared femoro-femoral VA ECMO, single-lumen cannula femoro-pulmonary artery (V-Pa), and double-lumen cannula right atrium-to-pulmonary artery (RA-Pa) support configurations in a swine model of ischemic aRVF-induced cardiogenic shock. Twenty-six adult German Landrasse swine were randomly assigned to the three study groups. Systemic oxygen delivery was the primary end-point; secondary end-points included hemodynamic parameters and complications. Systemic oxygen delivery remained stable during support without intergroup differences. Mean arterial pressure showed higher values in the V-Pa group compared with RA-Pa at 2 hours (65 ± 10 vs. 48 ± 8 mm Hg; p = 0.010) and 3 hours (62 ± 9 vs. 47 ± 10 mm Hg; p = 0.042). Mean pulmonary artery pressure was higher after V-A ECMO (20 ± 5 mm Hg) initiation compared with V-Pa (11 ± 5 mm Hg, p = 0.013) or RA-Pa (11 ± 3 mm Hg, p = 0.006) support. During support, the V-A ECMO group exhibited the lowest EtCO2 and highest carotid flow (p = 0.039 and p < 0.001, respectively). Challenges were noted with double-lumen cannulation due to anatomical constraints. Pulmonary artery cannulation-based support was noninferior to V-A ECMO in terms of oxygen delivery, with lower pulmonary pressures and preserved transpulmonary flow. Femoral vein-to-pulmonary artery configuration showed favorable short-term hemodynamics and easier cannulation compared with RA-Pa.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a large-animal model for dual-lumen venopulmonary extracorporeal membrane oxygenation using right atrium-to-pulmonary artery cannulation.Animal models and experimental medicine · 2026
- Impact of Cannulation on Venous Congestion, Right Ventricular Function, and End-Organ Protection During VV ECMO: A Computational Study.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- Hemodynamic effects of a novel counter-pulsatile system for extracorporeal membrane oxygenation.Perfusion · 2026
- Acute Right Ventricular Failure in Animal Models: Evidence, Limitations, and Future Directions.Artificial organs · 2026
- Beyond flow: a ventricular-load framework for VA-ECMO in cardiogenic shock.Frontiers in medicine · 2026
- The Impact of the Impella RP® Device on a Failing Right Heart: A Modelling and Simulation Approach to Ascertain Its Potential.Bioengineering (Basel, Switzerland) · 2026