Development of a large-animal model for dual-lumen venopulmonary extracorporeal membrane oxygenation using right atrium-to-pulmonary artery cannulation.
Benjamin Pequignot, Alma Revol, Guillaume Lebreton, Joel Nguyen, Erick Portocarrero, Bruno Levy, Mickael Lescroart
Service de Réanimation Polyvalente de Mercy, CHR Metz-Thionville, Ars-Laquenexy, France. · Inserm, DCAC, Université de Lorraine, Nancy, France.
Key points
From the paper's conclusion- This study establishes a reproducible large-animal model of dual-lumen VP ECMO suitable for procedural training, translational research, and future investigations.
Abstract
BACKGROUND: Venopulmonary extracorporeal membrane oxygenation (VP ECMO) using a right atrium-to-pulmonary artery configuration has emerged as an attractive strategy for right ventricular failure, bridge-to-lung transplantation, and selected cases of severe respiratory failure. Despite increasing clinical use of dual-lumen cannulas, dedicated large-animal models remain poorly described. We developed a reproducible swine model of VP ECMO using a dual-lumen right atrium-to-pulmonary artery cannula. METHODS: Twelve adult male Landrace pigs underwent attempted bedside cannulation through the right internal jugular vein. After ultrasound-guided vascular access, a pigtail catheter was advanced into the pulmonary artery under fluoroscopic guidance and exchanged for an ultra-stiff guidewire. A 29-Fr dual-lumen cannula was then positioned between the right atrium and pulmonary artery and connected to a centrifugal pump and membrane oxygenator. Animals were maintained on VP ECMO support for 12 h. RESULTS: Successful VP ECMO implantation was achieved in 8 of 12 animals (67%). Median maximal blood flow was 3.7 L/min (3.5-4.0). Median drainage and return pressures were -80 mmHg (-70 to -100) and 110 mmHg (100-122), respectively. Median pre-oxygenator venous oxygen saturation was 67% (65-75). Baseline pulmonary artery pressure was normal (20 mmHg [15-25]). Four procedures were unsuccessful, including three episodes of ventricular fibrillation and one cardiac tamponade. After refinement of the implantation technique, no clinically significant cannula migration or flow deterioration was observed during the 12-h observation period. CONCLUSIONS: This study establishes a reproducible large-animal model of dual-lumen VP ECMO suitable for procedural training, translational research, and future investigations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hemodynamic Effects of Three Different Mechanical Circulatory Support Strategies in Isolated Acute Right Heart Failure.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- Cannula Pairing Determines Distal Limb Perfusion During Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation: An Experimental Mock-Loop Study.Artificial organs · 2026
- The Early Assessment of a Newly Developed Maglev Extracorporeal Mechanical Oxygenation System: 14 Day In Vivo Study Report.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- Impact of Cannulation on Venous Congestion, Right Ventricular Function, and End-Organ Protection During VV ECMO: A Computational Study.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- VVECPella: Combined Venovenous ECMO and Impella 5.5 for Cardiopulmonary Failure.Seminars in cardiothoracic and vascular anesthesia · 2026
- Novel Use of a Distal Perfusion Catheter With a Removable Side Port in Patients on VA-ECMOJACC Case Reports · 2026