Feasibility of Electrode-Location Estimates Based on Preoperative CT-Imaging for Anatomy-Based Fitting in Cochlear Implant Recipients.
Nina Rubicz, Nikolaus Poier-Fabian, Paul M Zwittag
Department of Otorhinolaryngology, Head and Neck Surgery, Kepler University Hospital GmbH, Linz, Austria.
Key points
From the paper's conclusion- The use of preoperative scans to predict the frequency map for anatomy-based fitting cannot be recommended; however, when applied with caution, such simulations may serve as a useful starting point for fitting in special cases.
Abstract
OBJECTIVES: To investigate whether there is a difference between electrode frequencies estimated in OTOPLAN according to anatomy using a preoperative CT scan and electrode frequencies based on postoperative cone beam computer tomography (CBCT). STUDY DESIGN: Monocentric retrospective registry study. SETTING: Tertiary academic medical center. PATIENTS: Twenty-three CI recipients between 2004 and 2025. INTERVENTIONS: CI. MAIN OUTCOME MEASURES: Comparison between frequency maps and angular insertion depth predicted from preoperative measurements and estimated from postoperative DVT imaging data. In addition, the frequency map should be compared with that provided by the standard setting of the CI fitting software. RESULTS: When comparing preoperative CT and postoperative CBCT, there were no significant differences for electrode contacts 1 and 2. Estimated preoperative frequency values are closer to the postoperative measured values than to the standard settings. CONCLUSIONS: The use of preoperative scans to predict the frequency map for anatomy-based fitting cannot be recommended; however, when applied with caution, such simulations may serve as a useful starting point for fitting in special cases.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Feasibility of Ultra-Low-Dose Photon-Counting CT for Anatomy-Based Cochlear Implant Fitting: A Cadaveric Proof-of-Concept Study.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2026
- Automated Optimization of Patient-Specific Electro-Anatomical Models Fitted to Cochlear Implant SCINSEVarXiv · 2026
- Correlating Electrically Evoked Compound Action Potential Thresholds with Cochlear Implant Position Using Validated Computed Tomography-Based Electrode Localization.The journal of international advanced otology · 2026
- Automatic Detection of Extracochlear Electrodes in Cochlear Implants Using Electric Field Imaging: Bench and Clinical Validation.Audiology research · 2026
- Influence of basal-most electrode positioning on the accuracy of angular insertion depth predictions in cochlear implantation.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
- Key pre-operative CT parameters for cochlear implantation: a focused radiologic review with surgical relevanceNeuroradiology · 2026