Cornea

Detection of Endothelial Plaque in Microbial Keratitis Using Anterior Segment Optical Coherence Tomography: Findings From the METRIC Study.

Folahan Ibukun, Kamini Reddy, Subeesh Kuyyadiyil, Elesh Jain, Gautam Parmar, Nakul S Shekhawat

Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD; and. · SNC Chitrakoot, Chitrakoot, Madhya Pradesh, India.

Key points

From the paper's conclusion
  • SLE substantially underdetects endothelial plaques compared with ASOCT, which enables reproducible detection with excellent agreement. Outcome-based validation of the significance of this increased detection is warranted.

Abstract

PURPOSE: To evaluate intragrader and intergrader concordance of anterior segment optical coherence tomography (ASOCT) for detecting endothelial plaque in microbial keratitis, and compare ASOCT detection versus slit lamp examination (SLE). METHODS: Diagnostic concordance study of 150 eyes with microbiologically confirmed bacterial or fungal keratitis at a tertiary eye hospital. Two masked ophthalmologist graders independently evaluated ASOCT images for 2 morphologically distinct endothelial plaque subtypes (round and flat). We assessed intragrader and intergrader concordance and diagnostic agreement between ASOCT and SLE using kappa, sensitivity, and specificity. Logistic regression assessed factors associated with disagreement between ASOCT and SLE after adjustment for covariates. RESULTS: ASOCT showed near perfect intergrader agreement for detecting round endothelial plaques (kappa 0.88), flat endothelial plaques (kappa 0.84), and either plaque (kappa 0.88). Intragrader agreement was substantial to near perfect for both graders (kappa 0.70-0.86). SLE identified endothelial plaque in 6.0% eyes, whereas ASOCT detected round plaques in 32.7%, flat plaques in 43.3%, and either plaque in 55.3% of eyes. Using ASOCT as reference, slit lamp sensitivity was 16.3% for round plaques, 6.2% for flat plaques, and 9.6% for either, with specificity exceeding 94%. Poor visual acuity (logarithm of the minimum angle of resolution ≥1.0) was associated with disagreement for round plaques (adjusted odds ratio [OR] 5.04), flat plaques (adjusted OR 3.63), and either morphology (adjusted OR 3.98). Bacterial infection was associated with disagreement for any plaque (adjusted OR 4.56). CONCLUSIONS: SLE substantially underdetects endothelial plaques compared with ASOCT, which enables reproducible detection with excellent agreement. Outcome-based validation of the significance of this increased detection is warranted.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers