Agreement between Sirius Scheimpflug-Placido tomography and Anterion swept-source OCT in keratoconic eyes stratified by prior corneal cross-linking: a retrospective cross-sectional agreement study.
Kubra Erdogan, Metin Unlu, Furkan Ozer
Department of Ophthalmology, Division of Cornea, Erciyes University Medical Faculty, Kayseri, Turkey. · Department of Ophthalmology, Division of Cornea, Erciyes University Medical Faculty, Kayseri, Turkey. drunlumetin@hotmail.com.
Key points
From the paper's conclusion- Although ant-Ast and ant-BFT in the wCXL group and ACD, ant-Ast, posterior K1, and posterior Kmean in the woCXL group demonstrated no statistically significant fixed or proportional bias, the relatively wide LoA do not support interchangeable use of Sirius and Anterion for these measurements.
Abstract
AIM: This study aims to assess the agreement between the Scheimpflug-Placido tomographer (Sirius) and the anterior-segment swept-source optical coherence tomography (Anterion) in evaluating anterior segment parameters separately in keratoconus (KC) patients with and without corneal cross-linking (CXL). METHODS: A retrospective analysis was conducted on 108 eyes of patients with keratoconus (KC), divided into two groups according to previous corneal collagen cross-linking (CXL) status: eyes with prior CXL (wCXL group, n = 72) and eyes without CXL (woCXL group, n = 36). Evaluated parameters included anterior and posterior keratometric measurements, pachymetric measurements, anterior chamber parameters, corneal astigmatism, and corneal shape/elevation-related indices. Measurements from both devices were compared using Bland-Altman analysis, assessing fixed and proportional biases. Agreement between devices was interpreted based on the combination of absence of significant fixed bias, absence of proportional bias, and the width of the 95% limits of agreement (LoA). RESULTS: In the wCXL group, anterior astigmatism (ant-Ast) and anterior best-fit toric ellipsoid (ant-BFT) demonstrated the most favorable bias characteristics. In the woCXL group, ant-Ast, ACD, posterior K1, and posterior Kmean showed favorable bias characteristics. CONCLUSIONS: Although ant-Ast and ant-BFT in the wCXL group and ACD, ant-Ast, posterior K1, and posterior Kmean in the woCXL group demonstrated no statistically significant fixed or proportional bias, the relatively wide LoA do not support interchangeable use of Sirius and Anterion for these measurements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Concordance of Corneal Tomographic Measurements Obtained via Swept-Source Optical Coherence Tomography Versus Scheimpflug Tomography.Bioengineering (Basel, Switzerland) · 2026
- Measurement Repeatability and Concordance of Corneal Tomography in Keratoconus Using Anterion Versus Pentacam.Bioengineering (Basel, Switzerland) · 2026
- Repeatability and Reliability of Corneal Tomography in Keratoconus Patients with Corneal Allogenic Intrastromal Ring Segments.Beyoglu eye journal · 2026
- Repeatability of interpolated corneal tomography maps in healthy and keratoconus corneas before and after crosslinking.Acta ophthalmologica · 2026
- Establishing a precision reference benchmark for corneal epithelial aberration measurements using a new hybrid device across keratoconus stages.Eye and vision (London, England) · 2026
- Diagnostic Performance of Integrated Tomographic-Biomechanical Indices Across Keratoconus Stages in a Chinese Population.Translational vision science & technology · 2026