Study on phase-change melting characteristics of rigid catenary wires under dynamic separation process
Xiaokang Wang, Yang Song, Xufan Wang, Fuchuan Duan, Zhigang Liu
Southwest Jiaotong University
Key points
From the paper's conclusion- The results indicate that a larger separation distance leads to a greater liquid-phase area in the contact wire.
Abstract
Abstract The dynamic interaction between the pantograph and the overhead conductor rail (PC) system directly affects the current collection stability of electric locomotives. Distinct from previous work centered on transient arcing behaviour, this paper investigates the phase-change-induced melting and ablation characteristics of the rigid contact wire during a single complete PC dynamic separation process. Firstly, a multiphysics-coupled model of the PC offline arc is developed that accounts for energy transfer mechanisms during the transient arcing process, including Joule heating, thermal conduction and radiation. Subsequently, a phase-change melting model of the contact wire is established by incorporating the latent heat effects induced when the contact wire surface temperature reaches its melting point. Then, based on the dynamic simulation model, the obtained separation trajectory of the PC contact pair is applied to the numerical model to conduct a series of transient arcing simulations. Finally, the phase-change melting characteristics of the contact wire and their evolution are revealed under varying separation distances, current intensities and crosswind conditions. The results indicate that a larger separation distance leads to a greater liquid-phase area in the contact wire. Unlike the initial liquefaction time, the liquid-phase area is positively correlated with the current and negatively correlated with the crosswind speed. Additionally, compared to the PC separation process, transient arcing during the PC re-contact process induces a more pronounced thermal accumulation effect.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Arc Dynamics and Material Erosion of Pantograph-Catenary Contacts Under a Rotating Permanent-Magnet Field.Materials (Basel, Switzerland) · 2026
- From Thermal Ablation to Mechanical Fracture: Lightning-Caused Breakage of Insulated Conductors Under Thermal–Mechanical Coupling of Power-Frequency Follow Current ArcsEng · 2026
- Overheating Characteristics of Contact Defects in the Transition Circuit of Oil-immersed Power Transmission Equipment On-Load Tap ChangerEngineering Research Express · 2026
- Switching Overvoltages in High-Speed EMUs Considering VCB Arc CharacteristicsApplied Sciences · 2026
- Identification and application of pantograph-catenary contact force under high-speed operating conditionsEngineering Research Express · 2026
- Study on the reignition phase and magnetic field simulation of drawn vacuum arc in 126 kV axial magnetic field contactsPhysics of Plasmas · 2026