Switching Overvoltages in High-Speed EMUs Considering VCB Arc Characteristics
Cong Wu, Wantao Xu, Xiaoqian Liu, Hongyu Ge, Hao Yang, Fuqiang Tian
Key points
From the paper's conclusion- These results characterize operation-dependent voltage distributions and parameter effects, supporting the assessment of transient voltage stresses in onboard high-voltage equipment.
Abstract
Switching operations of onboard vacuum circuit breakers (VCBs) during electrical phase separation can induce transient overvoltages in high-speed electric multiple units (EMUs). This study develops a PSCAD/EMTDC model of the CR400AF high-voltage system, incorporating a combined Mayr–Cassie dynamic arc model for opening and a time-varying resistance model for closing. The voltage responses at the pantograph terminal (P1), VCB output terminal (P2), and traction transformer high-voltage input (P3) are investigated, together with the effects of switching phase and contact movement speed. Under representative switching conditions, the simulated voltage peaks at P1, P2, and P3 were 341.96, 63.95, and 38.90 kV during closing at 90∘, respectively, compared with 208.79, 77.08, and 54.71 kV during opening at 0∘. During closing, the maximum voltage rate of rise at P1 reached 1827.15 kV/μs. Phase scans show higher closing overvoltages near 90∘ and 270∘, but higher opening overvoltages near 0∘ and 180∘. Over a contact-speed range of 0.5–2.0 m/s, the largest closing and opening peaks occur at 0.6 and 1.8 m/s, respectively. A parameter perturbation analysis shows that simultaneous variations of ±10% in the selected flexible-conductor RLC parameters result in peak-voltage deviations below 5% under the representative opening and closing conditions. A nine-case multifactor study of closing phase, contact speed, and distributed parameters further identifies peak voltages ranging from 229.09 to 341.96 kV within the investigated combinations. These results characterize operation-dependent voltage distributions and parameter effects, supporting the assessment of transient voltage stresses in onboard high-voltage equipment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prestrike characteristics and dynamic dielectric breakdown mechanism of double-break vacuum circuit breakers under AC and DC voltagesAIP Advances · 2026
- The effects of asynchronous interruption on arc motion characteristics of a triple‑break medium-voltage DC air circuit breakerPlasma Science and Technology · 2026
- Optimization Design of Bearing Insulation for Traction Motors of High-Speed Trains under Overvoltage ImpulsesIEEE Transactions on Dielectrics and Electrical Insulation · 2026
- Effect of Breaking Speed on Plasma Distribution Characteristics During the Arc Extinction ProcessEngineering Research Express · 2026
- Study on phase-change melting characteristics of rigid catenary wires under dynamic separation processTransportation Safety and Environment · 2026
- Evolutionary Characteristics of Interfacial Defects Inside Vehicle-Mounted High-Voltage Cable Termination for High-Speed TrainsCSEE Journal of Power and Energy Systems · 2026