Arc Dynamics and Material Erosion of Pantograph-Catenary Contacts Under a Rotating Permanent-Magnet Field.
Bingquan Li, Huajun Dong, Ningning Wei, Ran Ji, Lei Huo
Department of Railway Rolling Stock, Liaoning Railway Vocational and Technical College, Jinzhou 121000, China. · School of Mechanical Engineering, Dalian Jiaotong University, Dalian 116028, China.
Key points
From the paper's conclusion- These results indicate that erosion mitigation is associated with both arcing energy and arc-root attachment-site renewal, and that the half-cycle at 10 Hz provides a favorable balance among arc migration, current-collection stability, and thermal-load dispersion, providing experimental guidance for selecting magnetic-drive parameters for PCS arcs.
Abstract
To mitigate localized erosion of pantograph-catenary system (PCS) contacts caused by random migration of arcs during contact loss, a periodic transverse magnetic field generated by a rotating permanent magnet was proposed to regulate arc motion. A synchronized high-speed imaging and electrical-signal acquisition platform was established to compare arc dynamics, current-collection characteristics, and carbon-electrode erosion under no field, a static field, and periodic fields of 5, 10, and 30 Hz at 120 V DC and 25 A, while SEM/EDS characterized surface morphology and elemental composition. The static field shortened the arcing duration and continuously stretched the arc column toward one side, but produced directional surface grooves. Under periodic fields, the arc column alternately deflected and contracted. Among rotating-field cases, 10 Hz yielded a normalized RMS current ratio of 72.923% and the lowest current fluctuation coefficient of 13.509%, whereas 30 Hz showed no further improvement in electrical or erosion performance. These results indicate that erosion mitigation is associated with both arcing energy and arc-root attachment-site renewal, and that the half-cycle at 10 Hz provides a favorable balance among arc migration, current-collection stability, and thermal-load dispersion, providing experimental guidance for selecting magnetic-drive parameters for PCS arcs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Study on phase-change melting characteristics of rigid catenary wires under dynamic separation processTransportation Safety and Environment · 2026
- A Novel Test Rig to Investigate Electrically Induced Damage in an Isolated Bearing ContactTribology Transactions · 2025
- Study on the reignition phase and magnetic field simulation of drawn vacuum arc in 126 kV axial magnetic field contactsPhysics of Plasmas · 2026
- Experimental Study on the Effects of Different Contact Structures on Cathode Spots in Vacuum ArcsEng · 2026
- Effects of Adding Ferromagnetic Material on Vacuum Arc MotionEng · 2026
- Molten metal flow and crater evolution during cathode spot retrograde motionPhysics of Fluids · 2026