EP07.32 Learning curve and early clinical outcomes of ROSA robot-assisted brain biopsy: a retrospective single-center cohort study
G A Brozek, S A Pilawska, E Grzywna, K Stachura, R M Krzyżewski
Key points
From the paper's conclusion- Conclusion ROSA robot-assisted brain biopsy showed a discernible but short learning curve, resolving within approximately 26 cases.
Abstract
Background The ROSA ONE Brain robotic platform offers an alternative to conventional frame-based stereotactic biopsy. We characterized the learning curve of its introduction at a single center and compared outcomes with contemporaneous conventional biopsies. Material and Methods We retrospectively analyzed 52 consecutive ROSA robot-assisted biopsies (January 2023 - January 2025), divided chronologically into tertiles. Procedural time, diagnostic yield, and complications (Landriel Ibañez classification) were compared across tertiles and against 139 conventional stereotactic biopsies. Results Median patient age was 62 years (IQR 50-69); 61.5% were female. Diagnostic yield was 86.0% overall. Procedural time followed a classic learning curve pattern: 65 min (IQR 30-110) in the first tertile, rising to 130 min (IQR 85-160) in the second, and falling to 80 min (IQR 66-132) in the third (Kruskal-Wallis p = 0.029). Complications occurred predominantly in the first half: 7/26 cases (26.9%) versus 1/26 (3.8%) in the second half (p = 0.038). All 8 complications were Landriel Ibañez Grade I-II; no Grade III or IV events occurred. Compared with conventional stereotactic biopsies, ROSA procedures were significantly shorter (median 85 vs. 140 min; p < 0.001), while diagnostic yield (86.0% vs. 87.9%; p = 0.802) and complication rates (15.7% vs. 24.6%; p = 0.238) were comparable. Conclusion ROSA robot-assisted brain biopsy showed a discernible but short learning curve, resolving within approximately 26 cases. Once established, the system achieves significantly shorter procedural times than conventional stereotactic biopsy with equivalent diagnostic yield and safety, supporting its integration into routine neurosurgical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EP07.35 The impact of robot-assisted frameless brain biopsy on performance differences between junior and senior neurosurgeonsNeuro-Oncology · 2026
- The impact of robot-assisted frameless brain biopsy on performance differences between junior and senior neurosurgeons.PloS one · 2026
- Robot-assisted versus conventional cranial stereotactic neurosurgery: a systematic review and meta-analysis of targeting accuracy, procedural efficiency, and safety.Journal of robotic surgery · 2026
- EP07.26 Utility of robot-assisted frameless neurosurgical biopsies - scoping review of current trendsNeuro-Oncology · 2026
- SURG-22 Outcomes and lessons from MRI‑Guided and CT-guided/robotic‑assisted stereotactic needle biopsies (SNB) of brainstem lesionsNeuro-Oncology · 2026
- SURG-27 Fixed gantry versus mobile cone‑beam CT in guiding Robot‑assisted stereotaxis: a neuro-oncologic experience of 66 patientNeuro-Oncology · 2026