Robot-assisted versus conventional cranial stereotactic neurosurgery: a systematic review and meta-analysis of targeting accuracy, procedural efficiency, and safety.
Yiqun Dong, Shuo Zhang, Yanxi Bao, Yuxuan Jiang, Baoying Liu, Zerui Li, Zhuoxin Wen, Tianxia Jia,
Department of Neurosurgery, Zhujiang Hospital, Southern Medical University, Guangzhou, 510282, Guangdong, China. · Department of Rehabilitation Therapy, School of Rehabilitation Medicine, Zhujiang Hospital of Southern Medical University, Guangzhou, Guangdong Province, China.
Key points
From the paper's conclusion- Few studies, bias, heterogeneity and sensitivity to interval estimation prevent conclusions of generalized clinical superiority across cranial stereotactic applications.
Abstract
Comparative evidence on robotic cranial stereotaxy spans different procedures, platforms and outcome definitions. We evaluated targeting accuracy, procedural efficiency, safety and clinical outcomes by surgical application. Five databases were searched through September 20, 2026. Twenty-one comparative studies were included. Accuracy was summarized using Hedges g and time using mean differences (conventional minus robotic). DerSimonian-Laird (DL)/Wald analyses were compared with alternative variance estimators and Hartung-Knapp (HK) intervals. Surgical applications and clinical outcomes were assessed separately. The exploratory three-study accuracy synthesis favored robotic assistance under DL/Wald (g=1.03, 95% CI 0.36-1.69; I2=78.5%), but its prediction interval crossed zero (- 0.189 to 2.242). REML/HK yielded g=1.03 (95% CI -0.41-2.47; P=0.092); modified HK gave a similar result. Inclusion of electrode-level SEEG also produced a confidence interval crossing zero. Two biopsy studies favored shorter procedure duration under DL/Wald (18.48 min, 95% CI 11.46-25.49), although HK intervals crossed zero. Total biopsy workflow time and intracerebral hemorrhage drainage duration were inconclusive. Risk-of-bias judgments were serious in 17 studies, critical in one, moderate in one, and some concerns in two. No consistent association between improved targeting and better clinical outcomes was established. Selected biopsy cohorts suggest technical accuracy and timing advantages with robotic assistance. Few studies, bias, heterogeneity and sensitivity to interval estimation prevent conclusions of generalized clinical superiority across cranial stereotactic applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- SURG-27 Fixed gantry versus mobile cone‑beam CT in guiding Robot‑assisted stereotaxis: a neuro-oncologic experience of 66 patientNeuro-Oncology · 2026
- Robotic systems in cranial surgery: a systematic review of accuracy, clinical outcomes, and adverse events.Neurosurgical review · 2026
- Do robotic needle systems improve precision and efficiency? Evidence from a systematic review and meta-analysis of clinical and preclinical studies.Journal of robotic surgery · 2026
- Trajectory Planning in Robotic Stereotactic Neurosurgery: From Cerebral Biopsy and Deep Brain Stimulation to AI-Augmented Decision SupportLife · 2026
- Robotergestützte Herzchirurgie – eine aktuelle ÜbersichtsarbeitZeitschrift für Herz-,Thorax- und Gefäßchirurgie · 2026
- Application of robot-assisted full-course visualized hematoma puncture, aspiration and drainage in basal ganglia intracerebral hemorrhage: a comparative study with robot-assisted surgery and neuroendoscopic surgeryBMC Neurology · 2026