SURG-22 Outcomes and lessons from MRI‑Guided and CT-guided/robotic‑assisted stereotactic needle biopsies (SNB) of brainstem lesions
Hsien-Chung Chen, Anudeep Yekula, Andrew Venteicher, Sharona Ben-Haim, Clark Chen
Key points
From the paper's conclusion- Intraoperative trajectory adjustments were made in 23.1% of MRI‑guided biopsies but were unnecessary in CT-guided/robotic-assisted biopsies.
Abstract
Stereotactic needle biopsy (SNB) of brainstem lesions presents unique challenges due to their location and surgical risks. This study evaluates the clinical outcomes of stereotactic biopsies of brainstem lesions using frame-based, MRI-guided, and CT-guided/robotic-assist techniques. Clinical outcomes were collected from SNB of brainstem lesions performed over a 15-year period (2011-2026) by a single surgeon using the Cosman-Roberts-Wells (CRW) frame (frame-based), the Clearpoint XG (MRI-guided), or the Globus Excelsius GPS (CT-guided/robotic-assist). Of the 24 brainstem biopsies, five were frame-based, thirteen were MRI-guided, and six were CT-guided robotic-assisted. The procedural times were comparable across techniques (median [IQR]: 168 [135.5, 196.5], 168 [145.5, 222], and 126 [95, 142] minutes for frame-based, MRI-guided, and CT-guided/robotic-assisted biopsies, respectively; p = 0.27). Diagnostic yield was 95.8% (23/24), with one nondiagnostic frame-based biopsy. The diagnoses included various forms of neoplastic, inflammatory, and indolent pathologies. There was one surgical morbidity (1/24 or 4.2%) involving a hematoma at the entry site. MRI-guided and CT-guided/robotic-assist biopsies showed comparable accuracy, with radial errors of 1.08±0.54 mm and 1.48±0.54 mm, respectively (p = 0.32). Intraoperative trajectory adjustments were made in 23.1% of MRI‑guided biopsies but were unnecessary in CT-guided/robotic-assisted biopsies. More samples were taken in MRI-guided and CT-guided/robotic-assist biopsies than in frame-based biopsies (1.0±0.0 v 3.11 + 1.45 samples, p < 0.0001). The length of hospital stay was comparable across biopsy methods (p = 0.66). 30-day readmission occurred in 20.8% of patients and was all attributable to corticosteroid-related issues. The pathology of brainstem lesions is diverse, and tissue diagnosis is warranted. MRI-guided and CT-guided robotic-assisted SNB enable intraoperative confirmation and adjustment, as well as increased tissue sampling, while maintaining a favorable safety profile.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Frameless VarioGuide biopsy for pediatric brainstem lesions in the molecular era: diagnostic performance and workflow characteristics in a comparative single-center series.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2026
- EP07.26 Utility of robot-assisted frameless neurosurgical biopsies - scoping review of current trendsNeuro-Oncology · 2026
- Diagnostic yield, safety, and molecular-era clinical utility of stereotactic biopsy for brainstem lesions: a contemporary systematic review and meta-analysis.Frontiers in surgery · 2026
- NCOG-54 Safety of frameless stereotactic brain tumor biopsy in a large contemporary seriesNeuro-Oncology · 2026
- SURG-11 Comparison of Frame-Based and Frameless Robot-Assisted BiopsyNeuro-Oncology · 2026
- SURG-14 Canonical stereotactic trajectories and technical considerations for neuro-oncologic procedures performed within the MRI bore: An atlas based on 121 consecutive proceduresNeuro-Oncology · 2026