Inter-rater and intra-rater reliability of quantitative ultrasound in preterm infants: an observational cohort study.
Angela N. Bachim, Shragvi Balaji, Covi Anne Tibe, Mamta Naik, M Yu-Carr, Cydney Meyer, Lakshmi Panjini, Mar Romero‐Lopez
Baylor College of Medicine · The University of Texas Health Science Center at Houston
Key points
From the paper's conclusion- Used quantitative ultrasound to measure the mid-tibia location in preterm infants and calculated inter-rater and intra-rater reliability.
- Intra-rater reliability at 1 mo post-birth and 36 wk PMA was excellent across all operators; inter-rater reliability was good at 1-mo measurements and excellent at 36 wk PMA.
- QUS is a reliable diagnostic tool and a feasible potential alternative to current diagnostic methodologies for MBPD in extremely preterm infants.
Abstract
= 81). The MiniOmni was the QUS device, and the smallest probe, CS probe (length 24 mm, range 2200-4700 m/s, and max depth 4.5 mm), was used for all subjects. Measurements were taken at the mid-tibia location. Inter-rater reliability was calculated using 2-way random-effects intraclass correlation coefficients (ICC); intra-rater reliability was calculated using 2-way mixed-effects ICC. 95% CI were calculated for each. Value of ICC estimates less than 0.5, between 0.5 and 0.75, between 0.75 and 0.9, and greater than 0.90 are indicative of poor, moderate, good, and excellent reliability, respectively. Intra-rater reliability at 1 mo post-birth and 36 wk PMA was excellent across all operators. Inter-rater reliability was more variable with good reliability at 1-mo measurements (0.84, 0.78-0.90, 95% CI) and excellent reliability at 36 wk PMA (0.94, 0.90-0.96, 95% CI). Our study demonstrated that QUS is a reliable diagnostic tool and a feasible potential alternative to current diagnostic methodologies for MBPD in extremely preterm infants.
Read the paper
Discussion · 1
Science Skim's AI key points, plus readers' public thoughts
- Used quantitative ultrasound to measure the mid-tibia location in preterm infants and calculated inter-rater and intra-rater reliability.
- Intra-rater reliability at 1 mo post-birth and 36 wk PMA was excellent across all operators; inter-rater reliability was good at 1-mo measurements and excellent at 36 wk PMA.
- QUS is a reliable diagnostic tool and a feasible potential alternative to current diagnostic methodologies for MBPD in extremely preterm infants.
Readers' thoughts
No reader thoughts yet.
Related papers
- Measurement Reliability and Trial-Sampling Effects in Ultrasound Assessment of Abdominal Muscle Thickness During the Active Straight Leg RaiseDiagnostics · 2026
- Intra- and Inter-Rater Reliability of Inter-Recti Distance Measurement Using B-Mode and Panoramic Ultrasound ImagingJournal of Clinical Medicine · 2026
- Sufficient Standardization? Evaluating the Reliability of an Inertial Sensor (BeyondTM) for Ankle Dorsiflexion After a Brief Familiarization PeriodSports · 2025
- Diaphragm ultrasound parameters and rapid shallow breathing index for predicting weaning failure in mechanically ventilated infants: a prospective observational PICU study.European journal of pediatrics · 2026
- Test-Retest Reliability of Myocene for Assessing Lower Limb Low-Frequency Fatigue: A Cross-Condition Reliability StudyMeasurement in Physical Education and Exercise Science · 2025
- Intra- and Inter-Rater Reliability of Primitive Reflex Assessments in Youth Football Athletes.Journal of functional morphology and kinesiology · 2026