Sufficient Standardization? Evaluating the Reliability of an Inertial Sensor (BeyondTM) for Ankle Dorsiflexion After a Brief Familiarization Period
Giacomo Belmonte, Alberto Canzone, Marco Gervasi, Eneko Fernández-Peña, Angelo Iovane, Antonino Bianco, Antonino Patti
University of Palermo · University of Verona
Key points
From the paper's conclusion- However, the measurement error analysis showed poor absolute agreement (LoA), indicating that the resulting measurement variability is considered clinically unacceptable for high-precision applications. (4) Conclusions: Beyond Inertial demonstrated excellent test-retest reliability for ankle dorsiflexion movements, although measurement error analysis showed considerable absolute error.
Abstract
(1) Background: Ankle joint range of motion is recognized as abnormal in individuals with ankle sprains and Chronic ankle instability (CAI), especially in the dorsiflexion movement. This research investigated the test-retest and inter-rater reliability of the Motustech Beyond IMU for dorsiflexion movement following only one hour of rater training and familiarization. (2) Methods: In total, 62 subjects were evaluated for the inter-rater reliability and test-retest with a one-week interval. The intraclass correlation coefficient (ICC), along with the Concordance Correlation Coefficient (CCC), was determined for each test of reliability. Standard error of measurement, coefficients of variation, limits of agreement (LoA) and minimal detectable change (MDC) were used for the measurement error analysis. (3) Results: Test-retest reliability was ranked excellent (ICC = 0.949) and very high (CCC = 0.897) for both ankle dorsiflexion measurements. On the other hand, Inter-Rater reliability was evaluated as good (ICC = 0.881-0.906) and very high (CCC = 0.783-0.811). However, the measurement error analysis showed poor absolute agreement (LoA), indicating that the resulting measurement variability is considered clinically unacceptable for high-precision applications. (4) Conclusions: Beyond Inertial demonstrated excellent test-retest reliability for ankle dorsiflexion movements, although measurement error analysis showed considerable absolute error. Consequently, it may be considered a reliable tool for single-rater monitoring of ankle dorsiflexion ROM in non-clinical settings such as general physical activity and amateur sports. Future research should investigate its potential role in injury prevention contexts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Measurement Properties of Hand‐Held Dynamometry for Ankle Strength Assessment: A COSMIN‐Based Systematic Review and Meta‐AnalysisMusculoskeletal Care · 2026
- Test-Retest Reliability of Myocene for Assessing Lower Limb Low-Frequency Fatigue: A Cross-Condition Reliability StudyMeasurement in Physical Education and Exercise Science · 2025
- Portable Dynamometry Is Reliable for Measuring Knee and Ankle Strength in Daily Practice: Results From a Systematic Review With Meta-analysis and Evidence Gap Map Using the COSMIN Methodology.The Journal of orthopaedic and sports physical therapy · 2026
- Reliability and measurement error of a wearable sensor for tibial acceleration and cadence in recreational runnersSports Engineering · 2026
- Inter-rater reliability of the ability for basic movement scale II-w: a revised clinical mobility scale adding a walking item.Frontiers in rehabilitation sciences · 2026
- Reliability of multilevel functional data in resistance training biomechanics - a pointwise mixed-modelling approach.Journal of biomechanics · 2026