A dual-phase study of a bioabsorbable venous vascular closure system: identifying predictors of failure and ensuring long-term safety in over 1,000 procedures
T Kanda, H Minamiguchi, T Hyogo, T Kanayama, Y Shibuya, T Sakio, M Matsumura, T Toyoshima,
Key points
From the paper's conclusion- We conducted a dual-phase study to identify predictors of procedural failure and evaluate long-term safety, specifically focusing on the management of rare infectious complications.
Abstract
Background As the volume of catheter ablation for arrhythmias increases, optimizing post-procedural hemostasis is essential for clinical workflow and patient comfort. The VASCADE MVP is an extravascular, bioabsorbable collagen-based venous vascular closure system (VVCS). We conducted a dual-phase study to identify predictors of procedural failure and evaluate long-term safety, specifically focusing on the management of rare infectious complications. Methods This study, conducted at our hospital, utilized a two-phase design. Phase 1 involved a mechanistic analysis of 203 consecutive venous access sites (70 patients) to identify predictors of hemostatic failure. Phase 2 consisted of an expanded safety evaluation of 1,162 consecutive procedures through October 2025. For atrial fibrillation ablation, an uninterrupted DOAC protocol was used with ACT targets of >300s (RF/cryoballoon) or >350s (pulsed-field ablation). Post-deployment, institutional protocol required 3–4 hours of gauze compression before ambulation. Results In Phase 1, the procedural success rate in the initial cohort was 94%. Multivariate analysis identified female sex (P=0.04), lower BMI (22.7 ± 3.5 vs. 25.0 ± 3.6 kg/m², P=0.02), and large-bore sheaths (10.4 ± 1.8 vs. 8.9 ± 1.2 Fr, P=0.01) as significant predictors of failure. In Phase 2, the safety cohort (n=1,162), delayed access-site cellulitis occurred in 0.6% (7/1,162) approximately one-month post-procedure. Management of these infections was limited to oral antibiotics and minor local management (incision, irrigation, and local debridement). Crucially, no patient required major surgical intervention, such as vascular reconstruction or bypass grafting, which are sometimes reported with suture-mediated closure devices. Conclusions This dual-phase evaluation confirms that the bioabsorbable VVCS is highly effective, although its efficacy is influenced by BMI and sheath size. The system’s primary safety advantage is its bioabsorbable nature, which allows rare infectious complications to be managed conservatively, thereby avoiding the invasive surgical interventions associated with permanent suture-based devices.Table
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Venous Vascular Closure System Versus Conventional Figure of Eight Suture Following Single Shot Device Pulmonary Vein Isolation: The VASC-AF Study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Safety and Efficacy of Two Venous Closure Devices Compared With Manual Compression After Atrial Fibrillation Ablation.Journal of arrhythmia · 2026
- Comparison of VASCADE MVP XL and Figure of 8 suture for vascular closure of the Faradrive sheath for pulsed field ablationEuropean Heart Journal · 2026
- Safety and Efficacy of the VASCADE MVP® XL Venous Vascular Closure System for Management of Femoral Venotomy Following Catheter‐Based Interventions Utilizing 16‐17F OD Sheaths: The AMBULATE EXPAND TrialJournal of Cardiovascular Electrophysiology · 2026
- Vascular closure strategies in pulmonary vein isolation to reduce vascular complications and facilitate same-day discharge.Heart rhythm O2 · 2026
- Vascular closure devices reduce access-site complications and improve procedural efficiency in adult electrophysiology: a systematic review and meta-analysis of 40,632 patientsEuropean Heart Journal · 2026