Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

Venous Vascular Closure System Versus Conventional Figure of Eight Suture Following Single Shot Device Pulmonary Vein Isolation: The VASC-AF Study.

Christian-Hendrik Heeger, Henning Rolfes, Louis Töllner, Tilman Maurer, Arian Sultan, Julia Vogler, Stephan Willems, Annalena Feibel,

Department of Cardiology, Asklepios Klinik Altona, Hamburg, Germany. · Department of Cardiology, Asklepios Klinik Nord, Hamburg, Germany.

Randomised · n=50

Key points

From the paper's conclusion
  • Among patients undergoing contemporary single-shot AF ablation, use of a bioabsorbable VCS significantly accelerated post-procedural recovery while maintaining a comparable major safety profile. Reduced access-site complications and improved patient-reported outcomes support VCS as an important component of enhanced recovery pathways following AF ablation especially in an ambulatory or Same-Day Discharge setting.

Abstract

AIMS: Optimization of femoral venous access management has become increasingly important as catheter ablation of atrial fibrillation (AF) continues to evolve towards greater safety with accelerated recovery pathways. We evaluated the efficacy and safety of a bioabsorbable venous vascular closure system (VCS) compared with a conventional figure-of-eight (F8) suture and manual compression following contemporary single-shot pulmonary vein isolation (PVI). METHODS AND RESULTS: VASC-AF was a prospective, multicentre, randomized controlled trial performed at three German electrophysiology centres. One hundred consecutive patients undergoing single-shot PVI were randomized in a 1:1 ratio to femoral venous closure using the VASCADE MVP VCS; (n=50) or conventional F8 suture (n=50). The primary efficacy endpoint was time to ambulation. The primary safety endpoint comprised major periprocedural adverse events requiring medical intervention before hospital discharge.Baseline characteristics and procedural variables were comparable between study groups. Median time to ambulation was significantly shorter following vascular closure with VCS compared with F8 sutures (120 [120-150] vs. 180 [180-240] min; P=0.015). Likewise, time to haemostasis (0.5 [0.5-2] vs. 1 [1-2] min; P=0.021) and time to discharge eligibility (2.5 [2.1-3.0] vs. 4.0 [3.0-5.0] h; P=0.019) were significantly reduced.Major adverse events occurred infrequently and did not differ significantly between groups. In contrast, vascular closure using VCS significantly reduced minor vascular access complications (6% vs. 26%; P=0.006), groin pain, and patient discomfort while improving overall post-procedural satisfaction. CONCLUSION: Among patients undergoing contemporary single-shot AF ablation, use of a bioabsorbable VCS significantly accelerated post-procedural recovery while maintaining a comparable major safety profile. Reduced access-site complications and improved patient-reported outcomes support VCS as an important component of enhanced recovery pathways following AF ablation especially in an ambulatory or Same-Day Discharge setting.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers