Vascular closure strategies in pulmonary vein isolation to reduce vascular complications and facilitate same-day discharge.
Isabelle N Bax, Marisa van der Graaf, Nina F T Keijzer, Marije de Lange, Jippe C Balt, Wouter R Berger, Vincent F van Dijk, Gerjan de Roest,
Department of Cardiology, St. Antonius Hospital, Nieuwegein, The Netherlands.
Key points
From the paper's conclusion- The use of a VCD in combination with an FO8 suture and protamine was significantly associated with lower observed access-site bleeding complications and optimized the workflow of PVI.
Abstract
BACKGROUND: Minor access-site bleeding is common after pulmonary vein isolation (PVI) for atrial fibrillation. Vascular closure devices (VCDs) may reduce bleeding, facilitating shorter bed rest and same-day discharge (SDD). OBJECTIVE: This study assessed the impact of closure strategies (Perclose™ ProStyle™ [VCD] and figure-of-8 [FO8]-suture) and mobilization protocols on access-site bleeding complications and length of hospital stay. METHODS: This single-center observational study included patients undergoing a primary PVI for atrial fibrillation between January 15 and December 31, 2025, at St. Antonius Hospital, the Netherlands. 4 protocols were evaluated sequentially: cohort 1: FO8-suture + 4 hours bed rest; cohort 2: VCD + 4 hours bed rest; cohort 3: VCD + 2 hours bed rest + 2 hours seated; cohort 4: VCD + FO8-suture + 2 hours bed rest + 1 hour seated. Primary outcome was in-hospital access-site bleeding, categorized by intervention. Secondary outcomes included SDD, time to discharge, unplanned overnight stay, and emergency room visits due to groin complications. RESULTS: A total of 738 patients were included (cohorts 1-4: n = 170, 161, 210, and 197, respectively). Baseline characteristics were comparable. 2 major bleeding complications occurred in cohort 1. Minor bleeding complications decreased across the 4 cohorts from 19.4% to 9.6% (P = .027). Female sex (odds ratio [OR], 1.52), protamine use (OR, 0.50), and cohort 4 protocol (OR, 0.38) predicted bleeding. SDD increased from 56.5% (cohort 1) to 67.0% (cohort 4, P = .168), without more unplanned overnight stays or bleeding-related emergency room visits. CONCLUSION: The use of a VCD in combination with an FO8 suture and protamine was significantly associated with lower observed access-site bleeding complications and optimized the workflow of PVI.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Venous Vascular Closure System Versus Conventional Figure of Eight Suture Following Single Shot Device Pulmonary Vein Isolation: The VASC-AF Study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Safety and Efficacy of Two Venous Closure Devices Compared With Manual Compression After Atrial Fibrillation Ablation.Journal of arrhythmia · 2026
- Vascular closure devices in electrophysiology procedures: Systematic review and meta-analysis.Heart rhythm O2 · 2026
- Suture-Mediated Vascular Closure Improves Same-Day Discharge in Atrial Fibrillation Ablation and Left Atrial Appendage Occlusion.JACC. Case reports · 2026
- Improved patient value after implementing same day discharge for patients undergoing pulmonary vein isolation.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Vascular closure devices reduce access-site complications and improve procedural efficiency in adult electrophysiology: a systematic review and meta-analysis of 40,632 patientsEuropean Heart Journal · 2026