科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Journal of the American Heart Association2026-01-30· Medicine

Prognostic Value of Artificial Intelligence–Enabled Electrocardiography–Derived Diastolic Dysfunction Grading and Trajectory in Patients Undergoing Transcatheter Aortic Valve Replacement

Chieh-Mei Tsai, Jwan A. Naser, Gal Tsaban, Eunjung Lee, Julia Wood, Allen S. Luis, Jeremy J. Thaden, Garvan C. Kane, Sorin V. Pislaru, Trevor J. Simard, Kevin L. Greason, Mackram F. Eleid, Vuyisile T. Nkomo, Jae K. Oh

原始摘要(英文原文)· Original abstract
Background Artificial intelligence (AI)–enabled electrocardiography has emerged as a tool for detecting cardiac dysfunction. The prognostic relevance of AI‐enabled electrocardiography–derived diastolic dysfunction (DD) in patients undergoing transcatheter aortic valve replacement had not been assessed. Methods We analyzed 3197 patients undergoing transcatheter aortic valve replacement for severe aortic stenosis between 2010 and 2023 with baseline 12‐lead ECGs processed by a validated AI model to classify diastolic function (grades 0–3). Multivariable Cox models and nested model comparisons assessed associations with all‐cause mortality, including a prespecified analysis in patients with indeterminate echocardiographic grading. Trajectories were defined by change in AI‐enabled electrocardiography DD grade (<2 versus ≥2) from baseline to 30‐day or 1‐year follow‐up. Results At baseline, 21% had grade 3, 57% had grade 2, 8% had grade 1, and 14% had grade 0 AI‐enabled electrocardiography DD. Higher grades were associated with adverse cardiac remodeling and comorbidities. Over a median follow‐up of 3.4 years, grade 3 AI‐enabled electrocardiography DD independently predicted mortality (hazard ratio [HR], 1.80 [95% CI, 1.47–2.20]; P <0.001). AI‐enabled electrocardiography DD improved prognostic discrimination beyond clinical and echocardiographic measures (ΔHarrell concordance statistic, 0.016; Δ χ 2 =57; P <0.001). Among 1259 patients with indeterminate echocardiographic grading, AI‐enabled electrocardiography added prognostic value (ΔHarrell concordance statistic, 0.02; Δ χ 2 =13; P =0.006). Worsening or persistently high‐risk trajectories were associated with increased mortality (HRs, 1.45–1.80; all P <0.05). Conclusions AI‐enabled electrocardiography–derived DD independently predicts mortality after transcatheter aortic valve replacement, adds value beyond echocardiographic grading, and enables dynamic risk stratification through longitudinal tracking.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Prognostic Value of Artificial Intelligence–Enabled Electrocardiography–Derived Diastolic Dysfunction Grading and Trajectory in Patients Undergoing Transcatheter Aortic Valve Replacement — 科研速览 Science Skim