Guide-sheath-assisted bailout technique for intra-procedural single-leaflet device attachment using the PASCAL system: a case report.
Masato Nukariya, Yuki Nishimura, Yoko Nakaoka, Kazuya Kawai, Hiroki Sugane
Department of Cardiology, Chikamori Hospital, 1-1-16 Okawasuji, Kochi 780-0052, Japan.
Key points
From the paper's conclusion- In conclusion, the guide-sheath-assisted retrieval technique can represent a potential bailout strategy for intra-procedural SLDA before full implant release during MTEER.
Abstract
BACKGROUND: Single-leaflet device attachment (SLDA) is a rare but serious complication of mitral valve transcatheter edge-to-edge repair (MTEER). When SLDA occurs after full device release, management options are limited. In contrast, intra-procedural SLDA recognized before full implant release may allow a specific bailout strategy. CASE SUMMARY: A 77-year-old man with severe degenerative mitral regurgitation (MR) underwent MTEER using the PASCAL Ace system because of high surgical risk. Initial device implantation reduced MR from severe to mild. However, after removal of both clasp lines during the release process, SLDA occurred at the posterior leaflet, resulting in recurrent severe MR. Although standard retrieval was no longer feasible, the implant remained connected to the steerable catheter. Under fluoroscopic and transoesophageal echocardiographic guidance, a guide sheath was advanced coaxially towards the implant. Controlled insertion of the guide sheath between the clasp and paddle, followed by gradual paddle opening, enabled leaflet disengagement and successful device retrieval without leaflet injury. A second implantation achieved a sufficient reduction in mitral regurgitation. DISCUSSION: This case demonstrates a novel bailout technique for intra-procedural SLDA. Successful retrieval requires precise coaxial device alignment, careful catheter manipulation, continuous monitoring of leaflet tension, and meticulous guidance using fluoroscopy and transoesophageal echocardiography (TEE). Importantly, prompt recognition of SLDA by TEE is a prerequisite for this technique. In conclusion, the guide-sheath-assisted retrieval technique can represent a potential bailout strategy for intra-procedural SLDA before full implant release during MTEER.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Successful Percutaneous Retrieval of an Embolized MitraClip From the Right Subclavian Artery.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Snare-Assisted Retrieval of a Mechanically Locked-Open TEER Device: A Novel Bailout Technique.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Double-Anchoring Transcatheter Mitral Valve Replacement: A Case Report of Septal Capture of Embolized Transcatheter Mitral Valves.Journal of the Society for Cardiovascular Angiography & Interventions · 2026
- Intraprocedural Embolization of a Tricuspid Edge-to-Edge Repair Device and Its Percutaneous Retrieval: A Case Report.Reports (MDPI) · 2026
- Challenging the limits of mitral-TEER: a PASCAL case in the anatomical 'red zone': a case report.European heart journal. Case reports · 2026
- Leaflet Perforation During Mitral Transcatheter Edge-to-Edge Repair: A Stepwise Dual-Device Strategy Leveraging Valve Geometry Modification.JACC. Case reports · 2026