B-395 Beyond Ethanol: Leveraging Routine Alcohol Testing to Detect Difluoroethane and Enhance Patient Safety
Laura Labay, Justine Drake
Key points
From the paper's conclusion- Accurate recognition of DFE during routine ethanol testing directly supports patient safety by preventing misclassification of intoxication and enabling timely and appropriate clinical evaluation.
Abstract
Background Failure to recognize difluoroethane (DFE) and other volatiles in samples submitted for routine ethanol testing can lead to misinterpretation of a patient’s intoxication status, delayed identification of inhalant abuse, and incomplete or delayed clinical decisions. DFE, a halogenated hydrocarbon commonly found in compressed gas products, is abused for its psychoactive effects. Acute DFE exposure is associated with central nervous system depression, cardiac arrhythmias, and sudden death, whereas chronic exposure may result in neurologic, renal, and hepatic toxicity. Although DFE may be detected during routine ethanol testing, it is an early eluting non-target analyte that can produce suboptimal chromatographic peak shapes or low response, making it easy to overlook. Establishing representative chromatographic examples provides a practical reference for laboratories, facilitating recognition of DFE and improving patient safety. Methods Samples submitted for routine ethanol testing were analyzed using dual-column headspace gas chromatography (GC-FID) with RTx®-BAC Plus 1 and Plus 2 columns. Chromatograms were systematically reviewed for potential DFE presence. Retention time was established during routine ethanol assay interference studies as part of method validation. Presumptive DFE findings were confirmed by gas chromatography–mass spectrometry (GC/MS). While DFE exhibited a retention time distinct from ethanol, peak morphology varied widely, from typical Gaussian peaks to low-response signals that could resemble baseline perturbations or early-eluting noise. Representative cases were selected to illustrate this variability and provide guidance for recognizing DFE despite suboptimal chromatographic appearance. Results DFE consistently demonstrated a retention time earlier than methanol on both analytical columns and distinct from ethanol across all samples. Although peak morphology varied, DFE-positive cases were accurately identified through GC/MS confirmation. Representative chromatograms demonstrate the range of DFE presentations observed, including patterns that could be overlooked during routine review. Reliable identification supported accurate recognition of DFE exposure and reduced the risk of misattributing findings to other causes of intoxication. Conclusion DFE can exhibit variable chromatographic peak morphology during routine ethanol testing, despite a retention time distinct from ethanol. During method validation, laboratories establish and document the retention time of DFE and other volatiles relative to ethanol, providing a reference framework for recognition in casework. Careful chromatogram review, supported by confirmatory GC/MS, allows reliable identification even when peak appearance is suboptimal and a DFE standard is not analyzed with each test. Sharing representative chromatograms offers practical guidance for laboratories and reinforces the role of clinical toxicology testing in diagnosis and patient safety. Accurate recognition of DFE during routine ethanol testing directly supports patient safety by preventing misclassification of intoxication and enabling timely and appropriate clinical evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Extended blood ethyl glucuronide persistence after controlled ethanol administration: Implications for ethanol-negative delayed DUI cases.Forensic science international · 2026
- Removal of Ethanol from Indoor Air by Ficus elastica Roxb.: Process Optimisation and Post-Removal Desorption Dynamics.Plants (Basel, Switzerland) · 2026
- Rethinking the Limit of Detection for Serum Ethanol: Evidence from a Clinical Laboratory.EJIFCC · 2026
- Evaluating Post-Analytical Stability of Blood Ethanol Samples Using Headspace-GC-FID.Journal of analytical toxicology · 2026
- Configuration-Specific Temporal Alignment of a Repurposed Wearable Fuel-Cell Alcohol Sensor with an MQ-3 Timing Proxy in a Laboratory Static-Headspace Chamber.Sensors (Basel, Switzerland) · 2026
- Rapid screening of ethylene glycol and diethylene glycol in raw materials and medicinal syrups using low-cost field deployable assaysScientific Reports · 2025