B-381 Comparison of Benzodiazepines Positivity Rates in Serum and Urine Specimens by LC-MS/MS in a Clinical Laboratory Setting
Zhe Cheng, Rachael Crookshanks, Agustin Pomperada, Roummel Ruvolo, Victor Vandell
Key points
From the paper's conclusion- In summary, our results demonstrate that urine represents the preferred specimen matrix for benzodiazepines testing.
Abstract
Background Benzodiazepines are a class of drug used as anxiolytics, sedative-hypnotics, muscle relaxants, and anticonvulsants. Commonly used benzodiazepines follow 3 metabolic patterns including: hepatic CYP metabolism to (a) active metabolites and (b) inactive metabolites and (c) direct glucuronidation in the kidney for excretion. Benzodiazepines such as diazepam have active metabolites with long half-lives contributing to significant accumulation risk, whereas those with inactive or minimally active metabolites, such as alprazolam and clonazepam, produce short half-lives without prolonged efficacy. The LOT drugs (lorazepam, oxazepam, and temazepam) bypass CYP metabolism and generate inactive glucuronide metabolites, resulting in a stable elimination rate, predictable half-lives, and minimal liver impact. Compared with urine, detection of benzodiazepines in serum focuses on drugs and/or their active metabolites and requires a blood draw but may better reflect recent usage, whereas detection in urine prioritizes inactive, active, and glucuronide metabolites. Urine involves less invasive collection and may better reflect usage over a longer term than serum. Methods Deidentified results from consecutive serum (n=1,668) and urine (n=32,598) specimens ran using CLIA -validated quantitative LC-MS/MS assays were reviewed. Cutoff levels for drug positivity were 2 ng/mL for alprazolam and 10 ng/mL for the other 13 analytes in serum and 25 ng/mL for 7-aminoclonazepam and a-hydroxyalprazolam and 50 ng/mL for the other 7 analytes in urine. Positivity rates were compared for 3 groups (a) diazepam, flurazepam, chlordiazepoxide, and their active metabolites; (b) alprazolam, triazolam, clonazepam, midazolam, and their inactive metabolites; and (c) lorazepam, and temazepam (LOT) and their glucuronidated metabolites. Results In the first group, the positivity rate was 6.0% for diazepam and 7.8% for nordiazepam in serum compared with 10.5% in urine. Other positivity rates were 1.4% for norfludiazepam, 1.4% for chlordiazepoxide, and 1.1% for norchlordiazepoxide in serum specimens and 0.1% for 2-hydroxyethylflurazepam in urine. In the second group, the positivity rate for alprazolam was 8.4%, while its metabolite a-hydroxyalprazolam was only 0.5% positive in serum compared with 21.7% in urine. Triazolam and a-hydroxytriazolam have the same positivity rate at 0.5% in serum, with a similar positivity rate of 0.3% for a-hydroxytriazolam in urine. The positive rate was 8.8% for clonazepam in serum and 10.9% for 7-aminoclonazepam in urine and 0.9% for midazolam in serum and 1.5% for a-hydroxymidazolam in urine. In the LOT group with glucuronidated metabolites in urine, the positive rate was 7.4% for lorazepam in serum and 13.9% in urine, 3.3% for oxazepam in serum and 20.7% in urine, and 3.9% for temazepam in serum and 15.9% in urine. Conclusion We found that for most benzodiazepines, analysis of their metabolites in urine provided the highest positivity rates, including diazepam, alprazolam, midazolam and LOT metabolites. Compared with serum specimens, positivity rates for all commonly detected benzodiazepines were higher in urine: 1.35-fold higher for nordiazepam (1.75-fold higher compared to diazepam); up to >40-fold higher for a-hydroxyalprazolam (2.6-fold higher compared to alprazolam); all glucuronidated LOT metabolites had markedly (∼1.9-6.3-fold) higher positivity rates in urine. In summary, our results demonstrate that urine represents the preferred specimen matrix for benzodiazepines testing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-396 Development and validation of an efficient clinical assay for quantification of benzodiazepines in serum by LC-MS/MSClinical Chemistry · 2026
- B-383 Development and Validation of a High-throughput LC-MS/MS Method for Routine Monitoring of Benzodiazepines in SerumClinical Chemistry · 2026
- Standardization of a Protocol to Quantify Benzodiazepines in Human Urine Samples Employing Gas Chromatography-Mass SpectrometryA Green Analytical Chemistry Approach.ACS omega · 2026
- Improved benzodiazepine detection with a beta-glucuronidase-containing immunoassay and implications on laboratory workflow.Clinica chimica acta; international journal of clinical chemistry · 2026
- 1 Expanding Benzodiazepine LC-MS/MS Confirmation Improves Diagnostic Accuracy and Clinical Interpretation in Toxicology TestingAmerican Journal of Clinical Pathology · 2026
- Urinary Detection Times and Excretion Profiles of Clonazepam and 7-Aminoclonazepam After a Single Oral Dose.Drug testing and analysis · 2026