B-396 Development and validation of an efficient clinical assay for quantification of benzodiazepines in serum by LC-MS/MS
Pragya Sharma, Yubo Chai, Loralie Langman, Paul Jannetto
Key points
From the paper's conclusion- Conclusion An efficient clinical assay was developed for confirmatory analysis of select benzodiazepines and their metabolites in human serum using a small sample volume.
Abstract
Background Benzodiazepines work as mild central nervous system depressants and are among the most prescribed drugs for the treatment of depression, anxiety, sleep disorders and alcohol withdrawal symptoms. Their pharmacological effect is mediated through activation of gamma-amino butyric acid (GABA)-mediated inhibitory neurotransmission in the brain. Although this class of drugs possesses a relatively low potential for addiction and side effects, individual metabolic differences such as impaired organ function, age-related or genetically determined drug metabolism challenges necessitate therapeutic drug monitoring. This study focuses on developing and validating a clinical assay for extraction and quantification of seven benzodiazepines and/or their metabolites in human serum. Methods Calibrators and quality controls (QC) were prepared by spiking benzodiazepines (chlordiazepoxide, oxazepam, nordiazepam, temazepam, diazepam, clobazam, n-desmethylclobazam; Cerilliant, USA) into human serum. Samples (50 µl) were extracted by protein precipitation with 90:10 acetonitrile:methanol (v/v) containing stable isotope labeled internal standards (chlordiazepoxide-d5, oxazepam-d5, nordiazepam-d5, temazepam-d5, diazepam-d5, clobazam-13C6, n-desmethylclobazam-13C6; Cerilliant, USA) in a 96-well plate. Following vortexing and centrifugation, supernatant was diluted with water. The extraction method was configured for automation on a Hamilton liquid pipetting system. Extracted samples were injected onto a LC-MS/MS (Sciex Triple Quad™ 6500) system. LC separation utilized a Restek Ultra Biphenyl 3 µm, 50x3.0 mm column with a 1.8 min method followed by tandem mass spec detection with data analysis performed using Sciex MultiQuant™ software. Results Assay validation was performed across 20 extracted runs on multiple days, three levels of QC and study unknowns. Intra- and inter-run imprecision for the QC concentrations was <10% for all benzodiazepines. Linearity was confirmed by linear regression analysis (r² > 0.98) across the analytical measuring interval (10-2000 ng/mL for most analytes, 10-3000 ng/ml for chlordiazepoxide and 100-10,000 for n-desmethylclobazam) with the limit of detection (LOD) determined to be <15% of the lower limit of quantitation (LLoQ). The signal-to-noise ratio for the LLoQ chromatogram was above minimum quantitation requirement of 10. The sample recovery was excellent with minimal matrix suppression, and no carryover was seen for all analytes. Accuracy was assessed by comparing measured concentrations of spiked samples with expected values or results obtained from an external laboratory. Regression slopes demonstrated minimal proportional bias, with all values within 1±0.1 and r²>0.98 with the % agreement within 80-120%. Conclusion An efficient clinical assay was developed for confirmatory analysis of select benzodiazepines and their metabolites in human serum using a small sample volume. The sample extraction was simple and well suited for automation platforms such as Hamilton pipetting systems. Protein precipitation was employed as a rapid and efficient extraction approach, offering significant advantages over more labor intensive techniques such as liquid–liquid or solid phase extraction. In addition, a short LC-MS/MS analysis method allows maximizing the use of instrumentation in a high-volume laboratory. All together the new assay provides adequate sensitivity, specificity, accuracy and throughput.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-383 Development and Validation of a High-throughput LC-MS/MS Method for Routine Monitoring of Benzodiazepines in SerumClinical Chemistry · 2026
- Standardization of a Protocol to Quantify Benzodiazepines in Human Urine Samples Employing Gas Chromatography-Mass SpectrometryA Green Analytical Chemistry Approach.ACS omega · 2026
- B-381 Comparison of Benzodiazepines Positivity Rates in Serum and Urine Specimens by LC-MS/MS in a Clinical Laboratory SettingClinical Chemistry · 2026
- 1 Expanding Benzodiazepine LC-MS/MS Confirmation Improves Diagnostic Accuracy and Clinical Interpretation in Toxicology TestingAmerican Journal of Clinical Pathology · 2026
- In vitro γ-aminobutyric acid A (GABAA) receptor activity and binding interactions at the α+/γ2– interface of 53 prescription and designer benzodiazepinesCommunications Chemistry · 2026
- A Validated Multi-Analyte Liquid Chromatography-Tandem Mass Spectrometry Method for Simultaneous Therapeutic Drug Monitoring and Targeted Toxicological Assessment of 54 Drugs and Metabolites in Human Serum.Journal of separation science · 2026