B-363 Multiplatform evaluation of calibration stability and factors influencing quantitative performance in LC–MS assays

Chao Sun, Zara Jalali, Yi Xiao, Edward Leung

Key points

From the paper's conclusion
  • Overall, calibration stability was significantly better in the immunosuppressant assays than in the vitamin assays.

Abstract

Background In routine LC–MS/MS practice, calibration curves are typically generated with each analytical run to ensure accuracy. However, if long-term calibration stability can be demonstrated, run-by-run calibration may not always be necessary, potentially reducing reagent consumption, instrument time, and operational cost. Analytical variability may arise from instrument platform differences, internal standard (IS) preparation and stock changes, chromatography hardware replacement (e.g., column installation), maintenance events, and IS selection strategy (structural analog versus isotope-labeled). We conducted a multiplatform evaluation to identify operational factors associated with concentration shifts and changes in assay precision across multiple analytes and LC–MS/MS platforms. Methods Analytical data for 16 analytes collected over a one-year period were exported and curated. Assays included immunosuppressant panel on Thermo Quantiva and on Waters TQ Absolute; fat-soluble vitamins (A, D, E) on Thermo Quantiva. For each run, analyte peak area and IS peak area were extracted, Area/IS ratios calculated, and compound-specific calibration equations applied to back-calculate concentrations. Levey-Jennings charts were generated for each back calculated QC level. Runs were grouped into chronological segments defined by documented operational events, including column installation, working IS preparation, IS stock changes, maintenance/performance warnings, and validation events. For each segment, QC-level mean concentration, SD, CV%, and percent shift relative to the preceding segment were calculated. For sirolimus, QC concentration CV% and IS area CV% were compared between structural analog and isotope-labeled IS approaches. Results Across all assays and instruments, within-segment analytical precision remained controlled, with all multi-run segment CVs below 20% and most below 15%. For sirolimus on the Waters platform, the isotope-labeled internal standard (Sirolimus-D) demonstrated superior concentration precision compared with ascomycin (Sirolimus-A). CVs ranged from 4.32–7.35% for Sirolimus-D versus 11.81–13.05% for Sirolimus-A across QC levels. In contrast, the largest absolute QC shifts were temporally associated with new internal standard preparation events, including working IS preparation or IS stock changes. On Thermo Quantiva ISD, IS-related segments demonstrated shifts up to 29.5%, exceeding those observed with column installation (maximum 14.6%) or maintenance events (=3.3%). In the vitamins assay, working IS preparation segments showed shifts up to 29.8%. Overall, calibration stability was significantly better in the immunosuppressant assays than in the vitamin assays. The immunosuppressant assays used a single analytical column and a highly standardized IS preparation process, with reconstitution from a new lyophilized vial each time followed by dilution in a volumetric flask. In contrast, the vitamin assays used multiple columns (potentially from different lots) and prepared working IS from concentrated stock solutions without using volumetric flasks, which likely contributed to greater variability. Conclusion Across multiple LC–MS/MS platforms and analytes, calibration curves demonstrated long-term stability when the same internal standard working solution was maintained, with acceptable precision within stable operational periods. The largest QC shifts were temporally associated with new IS preparation events, while column changes and maintenance had smaller effects. These findings suggest that calibration curves may be reused across runs, as long as the same working IS solution is maintained, thereby reducing unnecessary recalibration, saving time, and lowering operational cost.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

B-363 Multiplatform evaluation of calibration stability and factors influencing quantitative performance in LC–MS assays — Science Skim