Clinical Chemistry

B-333 Standalone AI-enabled app for automating and documenting clinical MS instrument performance

Omar Baba, Daisy Unsihuay Vila, Bernard Cook, Chi-tang Chen

Key points

From the paper's conclusion
  • We used generative AI-assisted tools to build a standalone desktop application encoding standardized logic for bench-level MS data review.

Abstract

Background Data review and troubleshooting for clinical mass spectrometry (MS) assays remain highly manual. In addition, documentation of routine crossover studies for calibrators, quality controls (QC), internal standards (IS), and analytical columns is a standard requirement in clinical laboratories to support regulatory compliance. Batch comparability assessments performed during crossover evaluations are not typically executable within vendor MS software, necessitating manual data extraction and comparison through spreadsheets with built-in decision rules. While this process may be manageable for single-analyte methods, multiplex assays and multi-instrument environments substantially increase the operational burden, making data review and documentation increasingly time-intensive. These gaps represent opportunities to strengthen troubleshooting capacity, record completeness, traceability, and audit readiness while improving workflow efficiency. We used generative AI-assisted tools to build a standalone desktop application encoding standardized logic for bench-level MS data review. Methods We developed a cross-platform desktop standalone application using generative-AI-assisted Python code generation, deployable on MS workstations without Python installation. Modules for calibrator, IS, new QC and new column validations feature a graphical user interface for metadata input (instrument ID, operator ID, date, lot number) and import of standardized text files (.txt) exported from SCIEX OS (Framingham, MA, USA). The app parses SCIEX OS data, applies predefined vendor nominal values stored in a version-controlled configuration backend, computes bias, %bias, slope variability, replicate metrics per predefined rules and generates color-coded summaries flagging repeats and ready for signature approval. Administrative functions support nominals, instrument, user updates with version history and governance. Calculations were validated across different data sets over two months against manual spreadsheets. Results The app successfully streamlined batch comparisons, calculations and documentation within a single, standardized and reproducible workflow. Automated parsing of instrument-exported data eliminated manual transcription and use of spreadsheet-based calculations, reducing time for documentation from 30 min to less than 5 min. Generated PDF reports provide uniform structure, predefined thresholds, and color-coded results, supporting transparent audit trails. The graphic user interface enforces completeness of key elements and enforces standardized logic, ensuring reproducibility despite staff variability in concordance with laboratory policy. Conclusion By embedding predefined percent accuracy thresholds, replicate logic, structured metadata capture, and uniform report generation into a user-friendly interface, this standalone tool supports consistent, reproducible data review while preserving expert oversight and without replacing existing vendor or laboratory information systems. The framework is scalable to additional assays and platforms and provides a foundation for future integration with laboratory information systems and longitudinal QC analytics.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

B-333 Standalone AI-enabled app for automating and documenting clinical MS instrument performance — Science Skim