Clinical Chemistry

B-342 Long run LC–MS/MS robustness in human plasma: a 30,000-injection evaluation of quantitative stability, carryover, and uptime on a triple quadrupole platform for clinical research

Gareth Hammond, Henry Foddy, David Farrell, Sally Hannam, Peter Hancock, Nikunj Tanna, Rob Plumb, Lisa Calton,

Key points

From the paper's conclusion
  • These findings support the platform’s suitability for high productivity workflows where consistent data quality, operational stability, and minimal downtime are essential.

Abstract

Background High throughput bioanalytical and research laboratories require LC–MS/MS systems capable of sustaining quantitative performance in complex plasma matrices over extended sequences with minimal downtime. Protein precipitation workflows, although simple and automation friendly, are sometimes avoided due to concerns about ion path contamination and signal degradation in long runs. This study assessed long term LC–MS/MS robustness using a plasma based workflow to evaluate signal stability, sub ng/mL accuracy and precision, chromatographic behaviour, carryover, and the effectiveness of routine user level maintenance. Naltrexone and its metabolite 6ß naltrexol were selected as representative analytes because published research describes considerable interindividual variability influenced by age related and genetic drivers of biotransformation. Their well characterised metabolic diversity and broad concentration profiles make them suitable model compounds for evaluating long run quantitative stability under clinical research conditions. Methods Opioid antagonist naltrexone and it’s active metabolite 6ß-naltrexol were quantified in human plasma using a Xevo™ TQ Absolute XR Tandem Quadrupole Mass Spectrometer with Step Wave™ XR Ion Guide coupled to an ACQUITY™ Premier LC System. A reverse phase method (2.1min run time; 5 µL injection; 0.8 mL/min; 60 °C column) was applied across 64 plates prepared with calibrators (0.2–100 ng/mL) and QCs at five levels, each plate analysed five consecutive times, yielding 30,720 total injections over ∼55 days. Bracketed calibration was applied; acceptance criteria followed bioanalytical method validation practice (±15 %, ±20 % at LLOQ). Carryover was assessed using bracketed blanks; a review by exception workflow in waters_connect™ Software supported data review. Only weekly source cone cleaning was performed for maintenance without the need for venting; columns were replaced as needed. Results Across the full sequence, excellent quantitative performance was sustained with continuous operation and no unscheduled downtime; >21 mL of human plasma was injected. All 320 plate runs met preset acceptance criteria for calibration linearity, QC accuracy/precision, and absence of carryover in subsequent blanks. At the LLOQ (0.2 ng/mL), replicate injections showed %RSD typically <3.0–3.5 %, with calculated concentrations largely within ±10 % of target; 99.6 % (naltrexone) and 99.8 % (6ß-naltrexol) of LLOQ QC results fell within the ±20 % criterion. Across all QC levels, 99.7 % of results satisfied acceptance limits. Performance metrics remained stable from early (∼1,000 injections) through late (∼30,000 injections) stages, indicating minimal ion path performance drift. Simple routine weekly cone cleaning without breaking vacuum were sufficient to maintain chromatographic integrity, sensitivity and signal to noise over the study. Conclusion The Xevo TQ Absolute XR Mass Spectrometer demonstrated sustained quantitative robustness, low carryover, and stable long run performance under high throughput, plasma rich conditions using a simple protein precipitation workflow. Hardware design elements that limit high mass ion transmission, combined with straightforward, user level maintenance, contributed to continuous operation without performance degradation. These findings support the platform’s suitability for high productivity workflows where consistent data quality, operational stability, and minimal downtime are essential. For Research Use Only. Not for use in diagnostic procedures.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

B-342 Long run LC–MS/MS robustness in human plasma: a 30,000-injection evaluation of quantitative stability, carryover, and uptime on a triple quadrupole platform for clinical research — Science Skim