Clinical Chemistry

A-306 Prevalence, Causes, and Mitigation Strategies for Pre-analytical Errors Occurring at The University Hospital of the West Indies Chemistry Laboratory

Shada Mohansingh, Matthew Preston, Donovan McGrowder, Lowell Dilworth

Observational

Key points

From the paper's conclusion
  • We recommend pushing for preventative strategies, such as implementing barcoding technology for identifying patients as automation reduces human errors, to label specimen immediately after collection, continuous education and training of medical personnel involved in blood drawing such as medical interns and phlebotomists and those transporting samples.

Abstract

Background Pre-analytical errors contribute approximately 70% of the errors that occur in chemistry laboratories. These errors undermine result accuracy, leading to misdiagnosis, delayed treatments, prolonged hospitalization and increased financial burden. Laboratories should therefore perform regular assessments for identifying pre-analytical errors as they are the major contributors to laboratory testing errors. This study investigated the rates and types of pre-analytical errors that occurred over a seven-year period at the Chemical Pathology Laboratory at The University Hospital of the West Indies (UHWI), and to develop preventative strategies. Methods This is a retrospective analysis of the pre-analytical errors logged unto the laboratory information system (LIS) from the July 2017 to May 2024 in the Laboratory. Samples rejected during this period were entered on the LIS with the stated reason. Categories for rejection included inappropriate sample, inappropriate volume, inappropriate form, administrative issues and unspecified causes. The data were analysed and the percentage error rates calculated for each year. Results A total of 3,476,236 tests were recorded over the timeframe. Of these, 3,551 rejected orders were recorded on the LIS. 170 orders belonged to the category “erroneous results.” Erroneous results can be considered pre-analytical errors, analytical errors or post-analytical errors and were therefore excluded even though most were presumed to be due to pre-analytical causes. 95.18% of the remaining 3,381 rejected orders were from serum/blood samples. The remaining 4.82% were from urine, CSF and stool samples. The overall error rate for the 7 years was found to be 0.097%. The highest recorded rate was in 2020 at 0.175%, when COVID-19 was at its peak. While the lowest rate was in 2018 at 0.071%. The inappropriate sample category contributed to 82.55% of the total pre-analytical errors. This included the sub-categories unlabelled specimen, inappropriately labelled specimen/incorrect preservative/expired tube, name on sample does not correspond with name on form, Incorrect registration number, no sample received/missing, other (wrong sample/sample clot/improper sample handling/covid protocol non-compliance) and haemolysed sample. The remaining categories: Administrative issues 7.13%, Inappropriate volume 5.24%, inappropriate form 4.41% and unspecified 0.68%. Conclusion Preanalytical errors are significant contributors to clinical chemistry laboratory inaccuracies. Inappropriate samples contributed to 82.55% of all pre-analytical errors. The error rate over an approximate seven-year period was found to be relatively low at 0.097% when compared to other laboratories worldwide. Although low, it remains a threat to patients’ safety, increases turnaround time and is costly. The year 2020 had the highest error rate at 0.175%, which coincided with covid-19 peak. This highlights the need for preventative strategies at reducing pre-analytical errors. This will be valuable, particularly, during periods when the healthcare system is under pressure and prone to developing errors. We recommend pushing for preventative strategies, such as implementing barcoding technology for identifying patients as automation reduces human errors, to label specimen immediately after collection, continuous education and training of medical personnel involved in blood drawing such as medical interns and phlebotomists and those transporting samples. Also, proper inventory of blood tubes is encouraged so a first in first out method is utilized.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers