B-274 Performance Evaluation of Direct ISE Method and Methodological Comparison Among Multiple Detection Platforms

Puguang Chen, Yixuan Liu, Wenlong Lu, Chaofan Li, Helu Liu

Key points

From the paper's conclusion
  • Therefore, this study conducted methodological comparison of the dISE module of BS-600M biochemical analyzer (Mindray, China) with the dISE module of ABL800 blood gas analyzer (Radiometer, Denmark) the iISE module of AU5800 biochemical analyzer (Beckman, USA) and the ICS-6000 (Thermo Fisher Scientific, USA) inductively coupled plasma mass spectrometer (ICP-MS), aiming to provide experimental basis

Abstract

Background Ion-selective electrodes (ISE) are the primary method for electrolyte detection in clinical laboratories. Currently, most clinical laboratories use automatic biochemical analyzers with indirect ISE (iISE) for quantitative electrolyte detection, while direct ISE (dISE) systems are mainly applied in blood gas analyzers, point-of-care testing (POCT) devices, and some models of automatic biochemical analyzers. Few studies have explored the comparability of ISE module test results across different platforms and blood sample types. Therefore, this study conducted methodological comparison of the dISE module of BS-600M biochemical analyzer (Mindray, China) with the dISE module of ABL800 blood gas analyzer (Radiometer, Denmark) the iISE module of AU5800 biochemical analyzer (Beckman, USA) and the ICS-6000 (Thermo Fisher Scientific, USA) inductively coupled plasma mass spectrometer (ICP-MS), aiming to provide experimental basis for clinical detection platform selection and result mutual recognition. Methods A total of 240 venous coagulated serum samples and 35 lithium heparin-anticoagulated arterial plasma samples were included. All samples were tested within 6 hours after collection, and methodological comparison experiments were completed within 1 hour, following the guidelines of CLSI EP series documents. Venous samples were evaluated on BS-600M, AU5800 and ICP-MS, while arterial samples were tested on BS-600M and ABL800. NIST SRM956d reference material was used to assess the accuracy of BS-600M’s dISE module, along with precision, linear range and analytical specificity. Results Methodological comparison of 140 cases between BS-600M and AU5800 showed Passing-Bablok slopes of 1.04, 1.00, 1.02 and Pearson correlation coefficients of 0.998, 0.985, 0.983 for Na?, K?, Cl?, respectively. For 100 cases between BS-600M and ICP-MS, the slopes were 0.98, 0.98, 1.01 and correlation coefficients were 0.926, 0.956, 0.753. For 35 arterial samples, the ion concentrations, absolute and relative deviation ranges were within acceptable limits. The module showed excellent accuracy (relative bias <2.5% for all three ions at three levels), good precision (intra-assay CV <0.5%, total CV <1.5%), and good linearity (R>0.99). Interference tests indicated acceptable bias under most conditions except K? bias >10% when hemoglobin =60mg/dL. Conclusion In conclusion, the dISE module of BS-600M shows good consistency across multiple platforms and sample types. It also has excellent precision, accuracy, linear range and anti-interference ability, with stable and reliable overall detection performance, fully meeting the needs of routine clinical laboratory testing.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers