B-195 Preliminary implementation of mass spectrometry (EXENT®) for the detection of oligoclonal bands in CSF

Nick Paciaroni, Marta Outón, José Luis Veiga, Mónica Pascual, Raúl Vidal, Teresa Cedena, Joaquín Martínez, Luisa María Villar,

Key points

From the paper's conclusion
  • Conclusion In this preliminary evaluation, EXENT® mass spectrometry showed excellent agreement with IEF for IgG OCB-positive and negative classifications.

Abstract

Background Detection of IgG oligoclonal bands (OCBs) in cerebrospinal fluid (CSF) by isoelectric focusing (IEF) with immunoblotting remains the reference laboratory method for demonstrating intrathecal immunoglobulin synthesis in multiple sclerosis (MS). Although analytically sensitive, IEF is labor-intensive, qualitative, and subject to interobserver variability. Mass spectrometry–based immunoglobulin profiling using the EXENT® Analyzer enables molecular-level detection of clonal intact light chains (iLC) through selective immunocapture and MALDI-TOF analysis, providing a digital and potentially more standardized readout. Methods Twelve paired CSF–serum samples previously characterized by IEF in a reference center were analyzed. Patterns included three mirror cases, three IgG+IgM positive cases, three IgG positive cases, and three negative cases. CSF samples were processed without external dilution; serum was analyzed both diluted and undiluted, with improved analytical performance observed in undiluted serum. The EXENT® workflow applies an internal ∼1:10 dilution during analytical processing. Independent expert interpretation was performed for both methodologies. Results EXENT® demonstrated 100% concordance with IEF for IgG OCB-positive and negative cases. Mirror-pattern cases showed limited agreement, with 1/3 fully concordant (33%). In one mirror case, only serum peaks were detected; in another, no differential signal was observed. Mirror-pattern cases were not associated with intrathecal synthesis or clinical MS diagnosis, consistent with their biological interpretation. These findings underscore the importance of appropriate alignment of serum and CSF immunoglobulin concentrations to minimize potential misclassification and preserve diagnostic specificity. No IgM oligoclonal patterns were detected by EXENT®, including samples classified as IgG+IgM positive by IEF. Analytical review indicated that IgG—and particularly IgM—concentrations in CSF were frequently near the system’s analytical limit of detection. The internal dilution step may reduce the effective concentration of intact light chains available for immunocapture, potentially influencing analytical sensitivity, especially for IgM detection. Conclusion In this preliminary evaluation, EXENT® mass spectrometry showed excellent agreement with IEF for IgG OCB-positive and negative classifications. However, reduced concordance in mirror patterns and absence of IgM detection suggest that analytical sensitivity in low-concentration CSF samples may be influenced by internal dilution. Further optimization of CSF-specific workflows and larger multicenter studies with formal statistical validation are needed to better define the role of mass spectrometry in CSF oligoclonal band assessment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers