From the paper's conclusion- These findings are consistent with previously published data, including a cohort of 271 patients in which EXENT identified a second M-protein >0.2 g/L in 13.3% of cases, suggesting that biclonal gammopathies may occur more frequently than previously recognized.
Abstract
Background Biclonal gammopathies (BG) are estimated to represent approximately 5% of clonal gammopathies; however, their true prevalence may be underestimated due to limited analytical resolution of conventional diagnostic techniques such as serum protein electrophoresis (SPE) and immunofixation electrophoresis (IFE). Scientific data comparing the detection of BG versus monoclonal gammopathies (MG) using advanced analytical platforms remain limited. Although previous studies suggest that BG do not significantly differ from MG in terms of progression or survival, BG have been reported to be more frequently associated with lymphoproliferative disorders. Improved detection may therefore be relevant for disease characterization and follow-up. Methods MALDI-ToF based M-protein measurement using the EXENT GAM assay was performed in a cohort of 119 patients evaluated for monoclonal gammopathies. Results obtained using EXENT were compared with routine SPE and IFE findings. Cases with discrepant interpretations regarding monoclonal versus biclonal patterns were identified and reviewed. Representative cases are illustrated in Figure 1. Results In four cases (3.4%), conventional SPE and IFE misclassified biclonal gammopathies as monoclonal due to insufficient resolution. In two patients, SPE and IFE identified a monoclonal IgG? component, while EXENT clearly demonstrated a biclonal IgG? pattern. In two additional patients, conventional methods showed a monoclonal IgG? profile, whereas EXENT revealed distinct biclonal IgG? components (Figure 1). These findings are consistent with previously published data, including a cohort of 271 patients in which EXENT identified a second M-protein >0.2 g/L in 13.3% of cases, suggesting that biclonal gammopathies may occur more frequently than previously recognized. Literature data indicate that while the presence of a second monoclonal component does not appear to significantly impact survival or progression compared to MG, BG are more often associated with lymphoproliferative diseases. Furthermore, the emergence of a second monoclonal component during MGUS follow-up has been linked to malignant transformation. Conclusion MALDI-ToF based EXENT analysis improves the detection of biclonal gammopathies compared with conventional electrophoretic techniques, revealing potential underdiagnosis in routine clinical practice. Given the limited size of existing studies and the likelihood of underestimated prevalence, larger prospective studies are needed to better define the clinical and prognostic significance of biclonal gammopathies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Monoclonal Gammopathy with Double M-bands Mimicking Biclonal Gammopathy: A Case Series.EJIFCC · 2026
- B-196 Comprehensive clinical validation of the Immunoglobulin Isotypes (GAM) assay for the EXENT® Analyzer assay in monoclonal gammopathiesClinical Chemistry · 2026
- B-039 Harmonizing M-protein analysis: an international, multi-center reproducibility study of the EXENT® System and evaluation of concordance to electrophoretic methodsClinical Chemistry · 2026
- B-195 Preliminary implementation of mass spectrometry (EXENT®) for the detection of oligoclonal bands in CSFClinical Chemistry · 2026
- Performance evaluation of an automated mass spectrometry system for the measurement and isotyping of monoclonal immunoglobulinsClinica Chimica Acta · 2026
- B-064 Bridging Quantitative MALDI-TOF Mass Spectrometry to IMWG Complete Response: Deriving a Serum Cut-off Equivalent to Negative ImmunofixationClinical Chemistry · 2026