Clinical Chemistry

B-108 Streamlining Oncology Diagnositics in Rural Settings: A Unified Plasma -Based Sample Protocol

Carrie Pruett

Key points

From the paper's conclusion
  • These findings demonstrated that plasma is an effective and efficient alternative to serum for laboratories seeking to improve performance and patient care.

Abstract

Background Serum samples used for immunoassays require extended clotting times, which can lead to delays, increased repeat rates, and workflow inefficiencies. Lithium heparin plasma offers advantages such as immediate centrifugation and compatibility across chemistry and immunoassay platforms. Implementing a single, standardized sample type can significantly improve operational efficiency, especially in office laboratories supporting rural communities where timely results and reduced redraws are critical. Methods A method comparison study was performed to evaluate the suitability of plasma versus serum for five immunoassay tests on the Tosoh AIA 2000 analyzer. Fifty (50) paired serum and plasma specimens were collected. Serum samples were allowed to clot for a minimum of 30 minutes, followed by 10 minutes of centrifugation. Plasma samples required no clotting time and were centrifuged immediately. Quality control materials were run according to ILCC laboratory protocol and remained within acceptable ranges throughout the 8-day study period. Results for paired serum and plasma samples were analyzed for correlation and performance characteristics. Data analysis followed Passing–Bablock Regression methodology as outlined in CLSI EP09 A3 guidelines for method comparison and bias estimation. Results Operational improvements were notable. Plasma reduced average turnaround time from 90 minutes to 46 minutes, a 48.89% reduction, due to elimination of the serum clotting step. Plasma also removed issues with residual fibrin, which had previously contributed to repeat testing and results delays (Figure1). Plasma demonstrated strong comparability with serum, achieving a 99% correlation coefficient (R) across all evaluated immunoassays. No significant biases were observed in Deming regression analysis of the 50 paired samples (Figure 2). Workflow efficiency improved across multiple areas. The laboratory was able to fulfill 94% of add on requests using existing plasma samples, reducing the need for patient re-sticks particularly important for patients with poor venous access. Overall sample handling was streamlined with fewer pre-analytic delays and fewer clot related issues. Data analysis was performed using Deming regression analysis method described in CLSI guidelines EP35 -Ed2 to evaluate the types of sample collection tubes and EP09 Measurement Procedure Comparison and Bias Estimation using patient samples. 50 samples with a result of > 99% of correlation coefficency (R) of serum vs. plasma (Figure 2). Conclusion Transitioning from serum to plasma for immunoassay testing significantly enhanced both analytical and operational performance. Plasma provided rapid processing without compromising result reliability, maintaining 99% correlation with serum across all evaluated assays. The substantial reduction in turnaround time, combined with fewer pre analytical issues and improved ability to accommodate add on testing, reflects a meaningful improvement in both workflow and patient experience. Standardizing plasma across chemistry and immunoassay platforms supports faster, more reliable testing while reducing burdens on staff and minimizing patient discomfort. These findings demonstrated that plasma is an effective and efficient alternative to serum for laboratories seeking to improve performance and patient care. References Clinical and Laboratory Standards Institute (CLSI). Assessment of Equivalence or Suitability of Specimen Types for Medical Laboratory Measurement Procedures.2nd ed. CLSI guideline EP35, Print Electronic USA, 2025. Illinois CancerCare Lab Procedures

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers