Clinical Chemistry

A-281 Overcoming Pre-Analytical Delays in Outpatient Oncology: Operational Impact of Thrombin-Based Rapid Clot Serum Tubes

Lisha Leonard, Nathanael Lexvold, Laura Price, Jennifer Nelson-Storlie, Brigitte Bagtuna, Amanda Marie Lopez, Lisa Rossini, Daniel Husen,

Key points

From the paper's conclusion
  • Rapid serum tubes (RST™) advertise reduced clot time from 30 to approximately 5 minutes.

Abstract

Background Laboratory results are critical in outpatient oncology, often used as a prerequisite to initiating chemotherapy; therefore, result turnaround time (TAT) is a key satisfaction metric. Slow or incomplete clot formation in serum separator tubes (SST™) contributes to delays in resulting core chemistry testing, including the Comprehensive Metabolic Panel (CMP). Although malignancy is often associated with hypercoagulability, many oncology patients also exhibit thrombocytopenia and hypofibrinogenemia; impairing clot formation and prolonging the customary 30-minute (SST™) clot time. Slow or incomplete clot formation can lead to additional manual and time-consuming workflows including managing instrument clot errors, manual aliquoting and centrifugation, validated pretreatment promoting fibrin formation with reptilase, and ultimately testing and reporting delays. Rapid serum tubes (RST™) advertise reduced clot time from 30 to approximately 5 minutes. The study aimed to evaluated transition from SST™ to RST™ in outpatient oncology clinics by evaluating the instrument-detected clot rate, reptilase rate, hemolysis rate, and TAT for CMP testing. Methods A pilot study was conducted at two Mayo Clinic Rochester, MN outpatient oncology collection sites. CMP specimens were collected in RST™ in place of SST™ (both Becton, Dickinson and Company, Franklin Lakes, NJ). Instrument flags due to clot-related errors were identified using middleware (Data Innovations, Colchester, VT). Clot rate was calculated as number of oncology CMP orders held with clot error divided by the total number of oncology CMP orders collected during the defined period. Pre-pilot clot data were collected 7/28/2025–8/1/2025 (n=419); pilot data 12/15/2025–12/19/2025 (n=410). Reptilase rate was calculated as number of oncology CMP orders with LIS reptilase comment divided by number of oncology CMP orders. Hemolysis rate was extracted from middleware (Roche Diagnostics, Indianapolis, IN) for 08/2025 (pre-pilot, n=1,598) and 12/2025 (pilot,709). Hemolysis rate was defined as number of samples with H-index =50 divided by total specimens with CMP orders. TAT metrics (mean, SD, and percentage meeting =120-minute goal) were collected 8/1/2025–8/31/2025 (pre-pilot, n=22,806) and 11/17/2025–12/31/2025 (pilot, n=432). Results During the pilot period, 432 collections with standalone orders for CMP were collected in RST™. The pre-pilot clot rate was 9.3% decreasing to 0.2% during pilot using RST. Reptilase use decreased from 1.2% to 0%. Hemolysis rate decreased from 2.1% to 0.2%. Mean TAT decreased from 78.8 to 69.0 minutes, with SD decreasing from 36.1 to 25.3 minutes. Compliance with the =120-minute TAT goal increased from 88% to 96%. Conclusion Impaired clot formation in SST™ exists as a pre-analytical obstacle to timely chemotherapy. RST™ substantially/consistently reduced clot-related instrument errors, eliminated reptilase use, decreased the hemolysis rate, and improved TAT performance. This targeted modification of collection tube selection represents a scalable, systems-level intervention that enhances pre-analytical quality without requiring additional instrumentation or staffing.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers