A-399 Analytical performance of enzymatic amperometric glucose and creatinine sensors for the Fluxergy multimodal point-of-care platform
Dmitriy Ruckodanov, Matthew Soto, Peter Lamberg, Esmeralda Ruiz-Garcia, Qinyi Yan, Cesar Gomez, Sahir Gandhi, Mariusz Banaszczyk,
Key points
From the paper's conclusion- Conclusion These results demonstrate that enzymatic amperometric glucose and creatinine sensors can achieve clinically relevant analytical performance on a scalable POC platform when paired with appropriate calibration and correction strategies.
Abstract
Background Point-of-care (POC) metabolic testing requires robust amperometric sensors capable of accurately quantifying clinically relevant analytes across wide concentration ranges while maintaining manufacturability and scalability. Enzymatic amperometric sensing of glucose and creatinine presents challenges related to non-ideal electrode behavior, enzyme kinetics, and matrix effects. This study evaluates the analytical performance of enzymatic glucose and creatinine sensors integrated into a multimodal POC platform with respect to FDA-cleared benchtop reference systems, with an emphasis on calibration, accuracy, and robustness across clinically relevant concentration ranges. Methods Amperometric glucose and creatinine sensors were evaluated using aqueous and biological samples spanning concentrations relevant to intended clinical use (glucose: 20–450 mg/dL; creatinine: 0.3–12 mg/dL). Sensors employed enzyme-based reaction cascades and were tested under controlled assay conditions. Sensor responses were compared against measurements obtained from a Nova Stat Prime Plus reference analyzer. Calibration approaches incorporated data-driven correction methods to account for nonlinear sensor response and electrode-specific variability. Analytical performance was assessed using correlation analysis, bias evaluation, and agreement with established clinical accuracy criteria. Manufacturing reproducibility was evaluated by testing sensors from multiple production batches. Results Both glucose and creatinine sensors demonstrated strong correlation with the reference analyzer across the evaluated concentration ranges in aqueous and biological matrices. Data-driven calibration and correction approaches improved linearity and reduced bias without introducing instability or increased variability. Most tested samples met applicable clinical accuracy expectations (as defined by the 2025 CLIA limits) across the reportable range for both analytes. Sensor performance remained consistent across production batches, indicating acceptable manufacturing reproducibility. Conclusion These results demonstrate that enzymatic amperometric glucose and creatinine sensors can achieve clinically relevant analytical performance on a scalable POC platform when paired with appropriate calibration and correction strategies. The findings support the feasibility of integrating multiple enzymatic assays into a single multimodal POC system and highlight the importance of data-driven approaches for characterizing and mitigating non-ideal electrochemical behavior in practical sensor implementation for diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-400 Development of a rapid point-of-care metabolic human blood panel for Na, K, Cl, and Ca diagnostics using the multimodal Fluxergy analyzerClinical Chemistry · 2026
- A-411 Evaluation of Point-of-Care Creatinine Analyzers: eGFR Categorization Accuracy for Safe Contrast AdministrationClinical Chemistry · 2026
- A multivariate approach to amperometric free chlorine monitoring: calibration, interference compensation, and application in water distribution systems.RSC advances · 2026
- A-412 To hydrate or not to hydrate? A comparison of the Siemens epoc, Abbott i-STAT, and Beckman Coulter DxC700AU IDMS traceable creatinine assays’ inter-platform variabilityClinical Chemistry · 2026
- Evaluating Analytical Performance of Commercial Screen-Printed Electrodes for Point-of-Care Uric Acid Sensing: A Comparative StudyApplied Sciences · 2026
- B-302 Body Fluids as Complex Analytical Metrices: Challenges in Validation and Analytical Performance of Automated Biochemistry AnalyzersClinical Chemistry · 2026