A multivariate approach to amperometric free chlorine monitoring: calibration, interference compensation, and application in water distribution systems.
Guglielmo Emanuele Franceschi, Lisa Rita Magnaghi, Gian Paolo Quarta, Raffaela Biesuz
Department of Chemistry, University of Pavia Viale Taramelli 12 Pavia PV 27100 Italy lisarita.magnaghi@unipv.it. · Onyax - Soluzioni IoT Via P. Bertolini, 9/L Vigevano PV 27029 Italy.
Key points
From the paper's conclusion- The proposed methodology enables robust semi-quantitative chlorine monitoring in real networks and represents a scalable solution for distributed early-warning systems in water quality management.
Abstract
Reliable monitoring of Free Available Chlorine (FAC) in drinking water is essential for ensuring disinfection efficiency and detecting contamination events, yet in situ amperometric measurements remain strongly affected by matrix variability and long-term instability. In this work, we present an optimized amperometric protocol for FAC determination implemented in NEMO, a low-cost, battery-powered Online Water Quality Monitoring (OWQM) device designed for continuous operation in water distribution systems. The working potential was identified through cyclic voltammetry and subsequently optimized using a multivariate Design of Experiments (DoE) approach. To address the strong dependence of the amperometric signal on pH and conductivity, two Multiple Linear Regression calibration strategies were developed: an in silico calibration model (Approach A) and a direct multivariate model (Approach B). Both approaches were built on 125 calibration samples and validated on an independent test set, showing a consistent agreement with the reference DPD spectrophotometric method. Limits of detection were evaluated through four complementary procedures, confirming suitability for typical FAC levels in drinking water. Field deployment on six devices over two months demonstrated overall stable performance, limited hysteresis, and reliable tracking of temporal FAC variations. The proposed methodology enables robust semi-quantitative chlorine monitoring in real networks and represents a scalable solution for distributed early-warning systems in water quality management.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A stabilized single-reagent TMB method for free chlorine monitoring in drinking water-related matrices.Environmental monitoring and assessment · 2026
- A-399 Analytical performance of enzymatic amperometric glucose and creatinine sensors for the Fluxergy multimodal point-of-care platformClinical Chemistry · 2026
- Innovative Technologies for the Online Monitoring of Chloroform in Water by MicroNIR/Chemometrics SystemsAnalytica · 2026
- Unsupervised Multivariate Anomaly Detection for Near-Real-Time Water-Quality Monitoring in District Metered Areas: A Three-Tier Benchmark Validated with Real-World AnomaliesWater · 2026
- Multi-criteria decision analysis and linear programming for optimal resource allocation in water quality monitoring networks: a case study of California’s EPA monitoring stationsEnvironmental Science and Pollution Research · 2026
- Lighthouse-shaped rapid identification device for acidic electrolyzed oxidizing water: A low-cost detection method based on conductivity differences.PloS one · 2026