A-355 Blood Gas Sample Storage Time Recommendations and Age Tracking Practices: A Survey of current practices across U.S. Health Care setting
Jamie Acero, Anne Skurup, Adrian Nastas
Key points
From the paper's conclusion- Overall, 83 (81 %) hospitals enforce analysis within 30 minutes or less, which is consistent with CLSI recommendations for minimizing pre-analytical variability (C46-A2).
Abstract
Background Blood gas analysis is highly time-sensitive, as delays between sample collection and analysis can lead to significant changes in pH, pCO2, and pO2, impacting clinical decision-making. Most blood gas analyzers also measure other time sensitive parameters like glucose and lactate. Several studies have been published on sample stability of blood gas samples within the last 5 years, concluding varying recommendations to storage time. This study aimed to evaluate current hospital practices regarding maximum allowable storage time and whether sample age is actively tracked. Methods A structured survey was distributed to healthcare professionals across multiple regions and departments. The survey captured institutional guidelines for maximum storage time, practices for tracking sample age, and demographic data (region and primary department). Descriptive statistics summarized responses. An open-ended question identified preanalytical pain points with the greatest potential for improvement, were included Results A total of 102 responses were analyzed. Respondents were geographically distributed across the United States: East (28), West (24), Midwest (24), and South (26), indicating balanced representation across regions. Participants represented diverse healthcare settings, with 42 working in point-of-care testing, 37 in laboratory medicine, 6 in respiratory therapy, and 17 in other areas such as emergency medicine, operating room, intensive care, perfusion, and nursing. For storage time guidelines, 44 (43 %) hospitals indicated that blood gas samples must be analyzed within 15 minutes, while 40 (39 %) reported a limit of 30 minutes. Only 5 (5 %) allowed analysis within 60 minutes, and 3 (3 %) specified other requirements. Nine (9%) respondents were unsure of their institution’s guidelines, suggesting gaps in staff awareness. Overall, 83 (81 %) hospitals enforce analysis within 30 minutes or less, which is consistent with CLSI recommendations for minimizing pre-analytical variability (C46-A2). Regarding sample age tracking, 67 (66 %) hospitals reported actively monitoring the time from collection to analysis, whereas 15 (15 %) do not track this parameter. Notably, 20 (20 %) respondents were unsure whether their institution tracks sample age, highlighting variability in workflow transparency, and a potential risk for undetected delays. Responses to the open-ended question indicated that improving timely transport and analysis was ranked as the second most valuable area for reducing preanalytical errors. Conclusion Most hospitals surveyed require analysis within 30 minutes or less. The variability is from 15 – 60 minutes which is in line with the varying results reported in the literature. Nearly one-third of respondents either do not track sample age or are unaware of tracking practices, which may compromise quality assurance and patient safety. These findings underscore the need for standardized protocols. The lack of consistent storage time recommendations and tracking practices may compromise operational compliance and quality assurance; a concern reinforced by respondents ranking this as the second most valuable area for improvement. Future efforts should focus on education and implementation of automated tracking systems to reduce pre-analytical variability and improve reliability in blood gas testing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pre-Analytical and Analytical Factors Affecting the Accuracy of Blood Gas Analysis—A Systematic Review with Structured Narrative SynthesisLaboratories · 2026
- A-356 Survey of Preanalytical Errors in Blood Gas Sample Collection and Analysis: Frequency, Impact, and Improvement Priorities Across U.S. Healthcare SettingsClinical Chemistry · 2026
- The Impact of Blood Gas Sample Waiting Time on Laboratory Parameters in Intensive Care Patients.Enfermeria clinica · 2026
- Effects of storage temperature and delayed analysis on routine biochemical and haematological test resultsScientific Reports · 2026
- Universal Versus Selective Sampling of Umbilical Cord Gases in University-Based, Academic Community-Based, and Private Practice Settings: A Cross-Sectional Study.Cureus · 2026