Effects of storage temperature and delayed analysis on routine biochemical and haematological test results
Adem Yağan, Zozan Akpolat, Duygu Korkmaz Yalçın, Hilal Şahin, Musa Yağan, Mehmet Emin Doğan, Zelal Yayla Kalay, Ümit Soylu,
Key points
From the paper's conclusion- Delayed analysis and storage temperature were associated with measurable changes in several routine biochemical and haematological test results.
Abstract
Blood samples collected in primary care may be transported to central laboratories, creating variable intervals between collection, processing and analysis. This study evaluated the effects of delayed analysis and storage temperature on routine biochemical and haematological test results under controlled laboratory conditions, with relevance to specimen handling and transport in primary care. This prospective, controlled, repeated-measures laboratory study included 32 healthy volunteers (16 women and 16 men) at Van Yüzüncü Yıl University Dursun Odabaş Medical Centre, Türkiye. Serum and ethylenediaminetetraacetic acid whole-blood specimens were stored at room temperature (18–24 °C) or 4 °C. Twenty-seven biochemical and 26 complete blood count parameters were measured at a common baseline and after 4, 8 and 24 h. Time effects were assessed separately for each storage condition using Friedman tests, followed by Wilcoxon signed-rank tests with Holm adjustment. Storage conditions were compared at each follow-up time using paired Wilcoxon signed-rank tests. Benjamini-Hochberg false discovery rate correction was applied to multiple testing. Statistical analyses were performed using Python and the SciPy scientific computing library. Delayed analysis produced time-dependent changes in several biochemical and haematological parameters, with the magnitude of change varying according to storage condition. At 24 h at room temperature, haematocrit increased by 7.61%, mean corpuscular volume by 7.51% and red cell distribution width-standard deviation by 15.95%, whereas mean corpuscular haemoglobin concentration decreased by 7.11%. Corresponding changes in these erythrocyte-related indices were substantially smaller at 4 °C. Platelet indices changed under both conditions, with mean platelet volume increasing by 4.85% at room temperature and 6.85% at 4 °C, and platelet large cell ratio increasing by 17.34% and 23.72%, respectively. Among biochemical analytes, triglycerides increased by 14.75% at room temperature and 11.55% at 4 °C, while total iron-binding capacity increased by 11.15% and 8.86%, respectively. Delayed analysis and storage temperature were associated with measurable changes in several routine biochemical and haematological test results. Refrigerated storage generally reduced time-dependent changes in several haematological parameters compared with room-temperature storage, although changes were also observed at 4 °C. These findings highlight the importance of considering both storage temperature and analysis delay when handling specimens collected in primary care. The statistically significant changes observed should not be interpreted as formal analytical or clinical stability thresholds.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Stability of 54 biochemical analytes in capped serum samples stored at 4-8 °C: a 72-h longitudinal evaluation.Clinical chemistry and laboratory medicine · 2026
- Short and Long Term Stability of Biochemical Analytes in Cattle Serum Under Varying Storage Conditions.Veterinary medicine and science · 2026
- A Prospective Study on Storage Related Changes in Packed Red Blood Cells Collected in CPDA-1 and SAGM.Indian journal of hematology & blood transfusion : an official journal of Indian Society of Hematology and Blood Transfusion · 2026
- A-355 Blood Gas Sample Storage Time Recommendations and Age Tracking Practices: A Survey of current practices across U.S. Health Care settingClinical Chemistry · 2026
- Evaluation of HbA1c stability in refrigerated blood samples: for how long are samples fit for use?Scandinavian journal of clinical and laboratory investigation · 2026
- Pre-Analytical and Analytical Factors Affecting the Accuracy of Blood Gas Analysis—A Systematic Review with Structured Narrative SynthesisLaboratories · 2026