A-356 Survey of Preanalytical Errors in Blood Gas Sample Collection and Analysis: Frequency, Impact, and Improvement Priorities Across U.S. Healthcare Settings
Jamie Acero, Anne Skurup, Adrian Nastas
Key points
From the paper's conclusion- This study assessed the frequency of these errors, their perceived impact on test quality, associated recollection rates, and key improvement priorities identified by respondents.
Abstract
Background Preanalytical errors in blood gas analysis can compromise patient safety and increase operational costs. Common errors include clots, air bubbles, hemolysis, insufficient mixing, incomplete removal of flush solution, and sample labeling issues. This study assessed the frequency of these errors, their perceived impact on test quality, associated recollection rates, and key improvement priorities identified by respondents. Methods A cross-sectional survey was distributed to healthcare professionals involved in blood gas sample handling across multiple U.S. regions. Respondents rated six preanalytical error types on three dimensions: (1) frequency of occurrence, (2) concern regarding impact on test quality, and (3) frequency of sample recollection due to the error, using a 5-point Likert scale (1 = never/not concerned; 5 = very often/extremely concerned). Demographic data included region and primary department. Of 102 respondents, regional representation was East (28), West (24), Midwest (24), and South (26). Departmental roles included point-of-care (42), laboratory (37), respiratory therapy (6), and other (17), with subcategories such as emergency medicine (6), operating room (5), intensive care unit (2), perfusion (2), cardio-thoracic surgery (1), and nursing (1). Respondents also provided open-ended feedback on top pain points for improvement. Results Mean frequency scores ranged from 2.24 (insufficient removal of flush solution) to 2.73 (air bubbles), indicating occasional occurrence. Concern over impact on test quality was higher, with means between 3.22 (insufficient mixing) and 3.64 (sample labeling errors), reflecting moderate to extreme concern. Sample recollection rates were generally low to moderate (means 2.52 to 2.72), with labeling errors showing the highest recollection impact (mean 2.72). Priority index analysis ranked labeling errors highest (2.90), followed by hemolysis (2.86) and air bubbles (2.85). Open-ended responses revealed three overarching improvement priorities: respondents emphasized the need for better sample handling and transport to reduce delays and maintain integrity, improved staff training and adherence to standardized collection techniques to minimize errors and repeat testing, and enhanced processes for sample mixing and air bubble removal to ensure accurate results and reduce retesting. Collectively, these priorities underscore the importance of standardized protocols, education, and process optimization to improve accuracy, efficiency, and patient safety. Conclusion Preanalytical errors in blood gas samples are perceived to have a significant impact on test quality, particularly labeling errors, which also drive higher recollection rates. Improvements in sample handling, staff training, and mixing protocols were consistently identified as critical strategies to enhance accuracy and operational performance. Targeted interventions and more research in these areas may yield the greatest improvement in patient safety and workflow efficiency.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-355 Blood Gas Sample Storage Time Recommendations and Age Tracking Practices: A Survey of current practices across U.S. Health Care settingClinical Chemistry · 2026
- Pre-Analytical and Analytical Factors Affecting the Accuracy of Blood Gas Analysis—A Systematic Review with Structured Narrative SynthesisLaboratories · 2026
- Types and frequency of preanalytical errors occurring in the hematology laboratory at Debre Tabor comprehensive specialized hospital, North Central, Ethiopia, 2025Scientific Reports · 2026
- Spectrum of Preanalytical Laboratory Errors in Clinical Biochemistry Laboratory in a Tertiary Care Center in Nepal.Kathmandu University medical journal (KUMJ) · 2025
- Pre-analytical errors in a high-volume Bangladeshi diagnostic centre: Prevalence, workload impact, and mitigation strategiesPLoS ONE · 2026
- Evaluation of Pre-Analytical Performance Using IFCC Quality Indicators, Six Sigma Metrics and Root Cause Analysis in a Biochemistry Laboratory-A Retrospective Study.Diagnostics (Basel, Switzerland) · 2026