A-278 Development and Deployment of Epic-Based Tools for Phlebotomy Efficiency and Quality: A Focus on Timed Draws
Jamie Haveman, Nadia Nehme, Kristine Guy, Ashley Rackow
Key points
From the paper's conclusion- Therefore, phlebotomy compliance with established collection protocols is essential for reliable test results.
Abstract
Background Reporting tools play a critical role in evaluating operational efficiency, optimizing workflows, and supporting high-quality patient care. One strategy for ensuring ongoing quality assurance is implementing quality indicators (QIs). The College of American Pathologists (CAP) requires laboratories to establish QIs across all testing phases—preanalytical, analytical, and postanalytical. Preanalytical errors can carry throughout the entire testing process, ultimately compromising the integrity of patient results. Therefore, phlebotomy compliance with established collection protocols is essential for reliable test results. To improve existing phlebotomy reports that did not account for phlebotomy zones, patient availability or refusals, or difficult sticks, custom Epic reports were created to more accurately capture all phlebotomy responsibilities. A pilot study was initiated to examine if these data could be translated into actionable QIs to monitor draw timeliness. Methods To overcome some of the challenges associated with developing QIs for inpatient phlebotomy, a custom report was built by the Johns Hopkins Epic/Beaker team. This specialized report only includes draws performed by the phlebotomy team, which serves the majority of the inpatient population (∼800 beds). Critically, the report contains a filter for deferred draws, which are instances in which specimen collection cannot be performed. The report also details the order time, scheduled collection time, and time of collection. Outliers were investigated to determine circumstances surrounding early or late timed draws, which led to the establishment of a 6-hour look-back window for deferrals. Once validated, the report was utilized to establish a baseline QI with a goal to collect 90% of all timed draws within +/- 1 hour of the scheduled collection time. Initial data was shared with phlebotomy leadership, and an educational flyer was distributed to all phlebotomy shifts. Additional interventions under consideration include Epic-based alerts, friendly shift-based competitions, and rezoning strategies. Results Preliminary data shows that before the intervention, an average of 89.7% of timed draws are collected within +/- 1 hour of the scheduled collection time. After the soft intervention, the percentage of timed draws rose to 91.1% before dropping to 84.3% and rising again to 90.7% and 93.1%. While education alone shows modest, temporary improvements, stronger interventions are underway to identify alternative strategies to increase compliance, including the development of report cards to facilitate friendly competitions between shifts, additional Epic-based interventions to prevent early or accidental collection of timed draws, and re-zoning based on draw volume and demand. These are expected to produce more lasting change and support improved workflows across shifts. Conclusion Reporting tools are essential throughout each aspect of the testing process, including preanalytical processes. A custom Epic phlebotomy report was generated to provide metrics for an ongoing QI initiative. Although a gentle educational intervention demonstrated modest temporary improvements, additional stronger interventions will be needed to see sustained improvements. While compliance with timed draws serves as an effective initial performance indicator, the broader objective is to ensure high compliance across all draw types. Improving phlebotomy practices reduces repeat collections, supports downstream analytical and postanalytical processes, and ultimately contributes to reliable laboratory results.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Preanalytical interventions to reduce hemolysis and improve specimen quality: a systematic review and meta-analysis.Laboratory medicine · 2026
- Evaluation of Pre-Analytical Performance Using IFCC Quality Indicators, Six Sigma Metrics and Root Cause Analysis in a Biochemistry Laboratory-A Retrospective Study.Diagnostics (Basel, Switzerland) · 2026
- An Autonomous Robotic Phlebotomy Device: Extended Analytical Validation and Real-World Hemolysis Assessment.Diagnostics (Basel, Switzerland) · 2026
- Extending external quality assessment to cover what is missing from the quality indicators we currently measure?Clinical chemistry and laboratory medicine · 2026
- Electronic patient blood management monitoring using routine health record data: A proof‐of‐principle study monitoring perioperative tranexamic acid useTransfusion · 2026
- Advancing patient safety through laboratory quality indicators in clinical pathologyCritical Reviews in Clinical Laboratory Sciences · 2026