Extending external quality assessment to cover what is missing from the quality indicators we currently measure?
Anushka Jayanetti, Tony Badrick
Royal College of Pathologists of Australasia Quality Assurance Programs, St Leonards, NSW, Australia.
Key points
From the paper's conclusion- The results of assay non-harmonisation are apparent on EQA reports, but laboratory staff are usually content if their results are within the APS for their method group.
Abstract
Clinical laboratories routinely use quality indicators to monitor pre- and analytic error. Post-analytic error is more difficult to define. It is usually defined as unacceptable turnaround times for results or corrected results, failure to notify a clinician of a critical result or a corrected report, or failure to hand over results or amended results. However, some post-analytic errors affecting patient safety and laboratory reputation are not managed well. These are the use of inappropriate reference intervals, the non-standardisation of abnormal-result flagging, and the non-harmonisation of methods. These errors are in plain sight, and yet laboratory staff fail to rank them as significant as other errors. The first two types of post-analytic error are not apparent to the laboratory unless a clinician files a complaint. This is partly because there are no EQA systems to provide peer comparison of these functions. The results of assay non-harmonisation are apparent on EQA reports, but laboratory staff are usually content if their results are within the APS for their method group. What is required is analytical standardisation and harmonisation; harmonisation of reference intervals and decision limits; standardised presentation and flagging; and quality assurance of the final report received by clinicians and patients. Solving this problem requires creating new forms of EQA focused on patient reports, whether electronic or paper, that highlight differences in report formats and information content.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Qualitative results in proficiency testing: a systematic review of evaluation practices and error integration.Clinical chemistry and laboratory medicine · 2026
- Evaluation of external quality assessment results of 15 clinical laboratory quality indicators in China from 2019 to 2021.Clinica chimica acta; international journal of clinical chemistry · 2026
- Clinical quality in UK laboratory medicine: current status and what the wider laboratory community can learnClinical Chemistry and Laboratory Medicine (CCLM) · 2026
- A-272 Benchmarking as a Tool for Performance Evaluation in Clinical Laboratory Quality IndicatorsClinical Chemistry · 2026
- A-306 Prevalence, Causes, and Mitigation Strategies for Pre-analytical Errors Occurring at The University Hospital of the West Indies Chemistry LaboratoryClinical Chemistry · 2026
- Quality Indicator-Driven Six Sigma Scale Assessment of Extra-Analytical Phases in Clinical Chemistry Laboratory-Insights from a Tertiary Care Hospital.Annals of clinical biochemistry · 2026