Clinical Chemistry

A-213 Impact of Hemolysis on Serum Osmolality Testing

Adam McShane, Jennifer Zakrajsek, Jessica Zakrajsek

Key points

From the paper's conclusion
  • Laboratories should assess serum osmolality specimens for hemolysis to ensure accurate results.

Abstract

Background Serum osmolality measurement is an essential clinical laboratory test to assist with the diagnosis and/or treatment of several conditions including toxic alcohol exposure, syndrome of inappropriate antidiuretic hormone (SIADH), diabetes insipidus (DI), and hyperosmolar states. Due to the vital nature of the test, it is commonly performed in hospital laboratories. A 2025 College of American Pathologists’ (CAP) proficiency testing survey listed almost 2,000 laboratories providing osmolality testing. Most laboratories (94%) reported they utilize an Advanced Instrument osmometer, which utilizes freezing point depression to determine osmolality. To provide high quality serum osmolality results, it is important to assess common interferences, such as hemolysis. Despite the common and essential nature of the test and frequency of hemolyzed samples, the instructions for use for the OsmoPro MAX (Advanced Instruments) does not provide hemolysis interference data. To fill this void, a hemolysis interference experiment was performed to ensure accurate osmolality results. Methods The hemolysis interference studies were performed on an OsmoPro Max automated osmometer (Advanced Instruments). Low and high osmolality pools, at approximately 230 and 320 mOsm/kg were divided into target and control pools. The target pools were spiked with hemolysate to achieve an H index of approximately 500 (500 mg/dL of hemoglobin or grossly hemolyzed). The target sample was then analyzed for osmolality and H index (c702, Roche Diagnostics). An equal amount of deionized water, as the added hemolysate to the target pool, was added to the control pool. The control pool was then utilized to dilute the target pool as outlined in Clinical & Laboratory Standards Institute (CLSI) document C56. Each pool was measured for osmolality and H index. Hemolysis interference was calculated by the variance of the target pools to the non-hemolyzed control pool. Interferograms were also constructed. Results At the highest H index tested of approximately 500, the low and high pools were falsely elevated by 3.8% and 4.1%, respectively. The osmolality results decreased with decreasing hemolysis and were within the laboratory’s acceptable variance of 2% for the low and high pools at an H index of 200 or moderately hemolyzed. Conclusion Grossly hemolyzed specimens will falsely elevate serum osmolality results measured with the OsmoPro Max osmometer. Laboratories should assess serum osmolality specimens for hemolysis to ensure accurate results.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A-213 Impact of Hemolysis on Serum Osmolality Testing — Science Skim