12 Systematic Evaluation of Hemoglobin, Icterus, and Turbidity Interference in Urine Chemistry Testing

Wenhan Cheng, Rachel Law, Ryan Shean, Sara Wyness, Lauren Pearson, Vrajesh Pandya

Key points

From the paper's conclusion
  • Given the central role of urine chemistry testing in assessing kidney disease, endocrinopathies, and drug exposure, the lack of systematic studies evaluating HIL interference in urine is a key gap.

Abstract

Background Interference from hemoglobin, bilirubin, and lipemia (HIL) is well characterized in serum/plasma chemistry testing, where these substances can introduce spectral interference or analyte‑specific contribution. Assay methodologies for many urine chemistry tests are identical or substantially similar to their serum/plasma counterparts. Although blood and bilirubin are commonly detected in urinalysis, lipemia from elevated triglycerides is uncommon. Urine turbidity, however, can arise from other causes—such as bacteria—which are frequently detected. Despite this, HIL index evaluation in urine remains uncommon. Given the central role of urine chemistry testing in assessing kidney disease, endocrinopathies, and drug exposure, the lack of systematic studies evaluating HIL interference in urine is a key gap. Objectives To (1) characterize relationships between measured hemoglobin, bilirubin, and bacterial concentrations and their corresponding H, I, and L indices generated by the Abbott Alinity c analyzer; (2) assess dose‑dependent effects of these interferents on a panel of urine chemistry and drugs‑of‑abuse assays; and (3) evaluate, using patient specimens, whether elevated L index values correlate with increased urine total protein or biomarkers of urinary tract infection (UTI), specifically nitrites and leukocyte esterase. Methods Three urine pools—normal, abnormal, and drug‑screening—were prepared from residual patient specimens and spiked with hemolysate, conjugated bilirubin, or cultured bacteria to simulate hemolysis, icterus, and turbidity. Hemoglobin, bilirubin, and bacterial density were quantified using Beckman Coulter, Roche c503, and VITEK DensiCHEK platforms, respectively. HIL indices, seven chemistry analytes, and ten drug assays were measured on the Alinity c system. Retrospective urinalysis data from the Sysmex UN‑3000 were correlated with corresponding L index results. Results Hemoglobin and bilirubin showed strong linear correlations with their respective indices (H index r² = 0.91; I index r² = 0.99), while bacterial density demonstrated a weaker association with the L index (r² = 0.71). Hemoglobin caused dose‑dependent positive interference in urine potassium, exceeding 10% bias at mid and high concentrations. It produced an initial negative bias in total protein, followed by marked positive bias at higher levels. Other analytes—including sodium, chloride, calcium, creatinine, urea, and all drug assays—remained within acceptance limits. Bilirubin caused dose‑dependent positive bias in total protein, exceeding the 10% allowable limit in one pool. Increasing bacterial density caused up to a five‑fold increase in total protein, while other analytes were unaffected. In patient specimens, L index values positively correlated with total protein. ROC analysis showed that elevated L index predicted nitrite (AUC 0.82, p = 0.02) and leukocyte esterase positivity (AUC 0.78, p = <0.0001). Conclusions H, I, and L indices reflect their corresponding interferents in urine. Hemoglobin, bilirubin, and bacteria can cause spurious elevation in urine total protein, with bacteria producing the greatest effect. Elevated L index values also associate with UTI biomarkers, supporting a role for lipemia index monitoring in urine testing workflows.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers