Clinical Chemistry

A-013 Turnaround Time Performance for Troponin I in a Core Laboratory

Robert Hawkins

Computational · n=44,635

Key points

From the paper's conclusion
  • This study evaluated TnI TTAT and RR performance in our high-throughput core laboratory against three indicators: TTAT <60 minutes (all priorities), RR <60 minutes (all priorities), and the more stringent RR <50 minutes specifically for Emergency Department (ED) and Urgent requests to reflect their higher clinical urgency Methods All TnI testing is performed on lithium heparin plasma samp

Abstract

Background Rapid turnaround time (TAT) for cardiac troponin I (TnI) is essential for management of acute coronary syndrome in the emergency department. The College of American Pathologists recommends a total TAT (collection to result reporting, TTAT) of =60 minutes as a key performance indicator. Many laboratories have faced challenges in reliably capturing specimen collection timestamps and choose to monitor within-laboratory TAT (receipt to reporting, RR) as a surrogate metric. Our laboratory information system has recently been upgraded to accurately record collection timestamps, enabling comprehensive TTAT monitoring for the first time. This study evaluated TnI TTAT and RR performance in our high-throughput core laboratory against three indicators: TTAT <60 minutes (all priorities), RR <60 minutes (all priorities), and the more stringent RR <50 minutes specifically for Emergency Department (ED) and Urgent requests to reflect their higher clinical urgency Methods All TnI testing is performed on lithium heparin plasma samples (5-minute centrifugation) using a Beckman Coulter Power Express pre-analytical automation system interfaced with two DxI 800 immunoassay analyzers. We extracted comprehensive TnI results from May through October 2025 (total n=44,635 samples) from our laboratory information system. Samples were systematically categorized by clinical priority [Emergency Department (ED), non-ED Urgent (U), non-ED Routine (R)], work shift (morning: 0700-1500, evening: 1500-2300, night: 2300-0700), and weekday versus weekend operation. For each stratification, we calculated median collection-to-receipt time (CR), median receipt-to-reporting time (RR), median TTAT, and the proportion of samples meeting each of the three performance targets. Performance was benchmarked against a 90% compliance goal, with CR versus RR comparisons used to localize process bottlenecks as preanalytical (CR) versus analytical/post-analytical (RR). Results Across all 44,635 TnI samples, median TTAT varied significantly by priority: 54.5 minutes for ED (n=20,976), 56.3 minutes for Urgent (n=1,707), and 59.0 minutes for Routine (n=17,530). Despite these acceptable medians, the proportion meeting TTAT <60 minutes fell short of the 90% target: 66.6% (ED), 59.1% (U), and 52.4% (R). Within-laboratory performance was substantially better, with RR <60 minutes achieved in =95.9% across all priorities and RR <50 minutes met in 94.2% (ED), 93.4% (U), and 93.5% (R). Shift analysis revealed clear operational patterns: night shift demonstrated optimal performance (median TTAT 51.7 minutes; 71.5% <60 minutes; median CR 14 minutes), evening was intermediate (55.3 minutes; 63.3%; CR 17 minutes), and morning showed the poorest results (59.7 minutes; 50.9%; CR 20 minutes). The morning shift's relative underperformance was driven primarily by prolonged preanalytical CR rather than RR times. Weekend operation showed modest advantages (median TTAT 55.2 vs 56.8 minutes weekdays; TTAT <60% of 62.7% vs 59.0%), with perfect RR <60 minutes compliance (100%) on weekends versus 96.1% weekdays. Conclusion This comprehensive 6-month analysis demonstrates excellent analytical performance (RR targets consistently met or exceeded) but suboptimal total TAT achievement, particularly during high-volume morning weekday periods. The disparity between strong RR metrics and TTAT shortfalls, combined with prolonged CR during peak periods, clearly identifies preanalytical processes as the primary improvement challenge.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers