Clinical Chemistry

A-294 Impact of Implementing High Sensitivity Troponin in a Dedicated Emergency Department Laboratory

Stephanie Hart, Ryanne Lenderman, Allison Hermane, Jonathan Tucci, Joesph Wiencek

Key points

From the paper's conclusion
  • Conclusion Our study shows a significant decrease in turnaround time after establishing hs-cTnT testing within the ED laboratory with no significant impact on hemolysis rates.

Abstract

Background In 2022, there were 129 million emergency department (ED) visits for patients 15+ years of age in the United States with approximately 8.1 million (6%) presenting for chest pain. For patients presenting to the ED with chest pain, high sensitivity cardiac troponin (hs-cTn) is a key diagnostic marker for myocardial infarction with a greater than 99% negative predictive value for myocardial infarction at 3 hours. At our institution, patients with chest pain undergo hs-cTn (high sensitivity troponin T, hs-cTnT) testing at 0 and 3 hours. Prior to this study, all ED hs-cTnT samples were transported to the core laboratory for testing primarily through pneumatic tube transport. On December 10, 2025 the hs-cTnT testing went live in the dedicated ED laboratory. This study aims to assess the impact of establishing hs-cTnT testing within the ED laboratory on test turnaround times and hemolysis rates. Methods To assess the impact of establishing hs-cTnT testing within the ED laboratory, de-identified test turnaround time and gross hemolysis rates (cancel) were extracted from the laboratory information system for the following time periods: December 10, 2024 thru February 10, 2025 (pre-go-live) and December 10, 2025 thru February 10, 2026 (post-go-live). Patient age and sex were also collected. Test turnaround time was defined as the time interval between in lab and result availability. A process map was performed pre- and post-go-live implementation (Figure 1). Results Establishing hs-cTnT testing within the ED laboratory decreased the number of steps in the laboratory workflow from sample in lab to release of results by 10 steps (pre-15 steps, post-5). Over the three-month pre-go-live period (December 10, 2025), the adult ED ordered a total of 6,708 timed stat hs-cTnT tests. Over the three-month post-go-live period following establishing the hs-cTnT testing within the ED laboratory,188 timed stat hs-cTnT tests. Pre- and post-go-live rates of test cancelation due to sample hemolysis were comparable at 2.8% (n=186) and 2.8% (n=172), respectively. Of the timed stat tests that resulted, there was a significant reduction in the number of tests above the internal 45-minute turnaround time target from 23% (n=1514) pre-go-live study period and 3.5% (n=209) post-go-live (p=0.0001). Conclusion Our study shows a significant decrease in turnaround time after establishing hs-cTnT testing within the ED laboratory with no significant impact on hemolysis rates.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers