Dosimetric comparison of automated noncoplanar volumetric-modulated arc therapy and intensity-modulated proton therapy for total scalp irradiation in angiosarcoma of the scalp.
Shoki Inui, Natsuo Tomita, Taiki Takaoka, Akane Matsuura, Yoshihiro Ueda, Shingo Ohira, Yuya Nitta, Sayaka Kihara,
Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuou-ku, Osaka, 541-8567, Japan. · Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan.
Key points
From the paper's conclusion- HA and IMPT offer complementary advantages for TSI in AS. HA improves dose homogeneity, reduces intermediate-to-high brain dose, and enhances treatment efficiency; conversely, IMPT better limits low-dose brain exposure and spares critical neural and ocular structures. Modality selection should be individualized according to patient-specific clinical needs.
Abstract
OBJECTIVES: To compare the dosimetric performance of HyperArc (HA) and intensity-modulated proton therapy (IMPT) for total scalp irradiation (TSI) in patients with angiosarcoma of the scalp (AS). METHODS: HA and IMPT treatment plans were retrospectively generated for 27 patients with AS. Prescription doses of 70 and 56 Gy (relative biological effectiveness [RBE]) in 35 fractions were delivered to targets 1 and 2, respectively, using a simultaneous integrated boost technique. HA was optimised to planning target volumes, whereas IMPT employed clinical target volume-based robust optimisation. Dose-volume parameters for targets and organs at risk were compared. Beam-on time was evaluated. RESULTS: Both techniques achieved adequate target coverage within dose constraints; HA demonstrated superior dose homogeneity and conformity for target 1, whereas IMPT exhibited greater dose heterogeneity. IMPT significantly reduced low-dose brain exposure [V5 Gy (RBE)] and high-dose exposure to the optic pathway, eyes, lenses, and hippocampus. HA significantly reduced intermediate-to-high brain exposure [V10-V60 Gy (RBE)], mean brain dose, and parotid dose. Moreover, HA achieved a shorter beam-on time. CONCLUSIONS: HA and IMPT offer complementary advantages for TSI in AS. HA improves dose homogeneity, reduces intermediate-to-high brain dose, and enhances treatment efficiency; conversely, IMPT better limits low-dose brain exposure and spares critical neural and ocular structures. Modality selection should be individualized according to patient-specific clinical needs. ADVANCES IN KNOWLEDGE: This study presents a direct dosimetric comparison of HyperArc and intensity-modulated proton therapy for total scalp irradiation in angiosarcoma of the scalp, demonstrating complementary strengths that may guide individualized modality selection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Dosimetric and Biological Comparison of Volumetric Modulated Arc Therapy and Adaptive Aperture Proton Therapy for Hippocampal-Sparing Whole-Brain Radiotherapy.Technology in cancer research & treatment · 2026
- Updated dosimetric comparison of HDR interventional radiotherapy including 60Co sources versus VMAT and electron beam therapy for NMSC.Radiation and environmental biophysics · 2026
- Dynamic Proton arc therapy for paediatric parameningeal rhabdomyosarcomaJournal of Applied Clinical Medical Physics · 2026
- A Unified Planning Platform Comparison of VMAT, Helical Tomotherapy, and IMRT in Nasopharyngeal Carcinoma: Dosimetric Superiority and Organ Sparing AnalysisTechnology in Cancer Research & Treatment · 2026
- Comparative Dosimetric Evaluation of Tomotherapy with a 1-cm Field Width versus Volumetric-modulated Arc Therapy for Whole-brain Radiotherapy with Hippocampal Avoidance.Journal of medical physics · 2026
- Platform-specific comparison of IMRT and VMAT angular resolution for Ethos-based online adaptive radiotherapy in cervical cancer.Frontiers in oncology · 2026