Dynamic Proton arc therapy for paediatric parameningeal rhabdomyosarcoma
Andreas Havsgård Handeland, Hardev Singh Grewal, Camilla Grindeland Boer, Daniel J. Indelicato, Kristian Smeland Ytre‐Hauge, Helge Henjum, Camilla Hanquist Stokkevåg
Key points
From the paper's conclusion- LET optimization in the proton plans achieved LET improvements in both target and OARs without compromising dose.
Abstract
Background Parameningeal rhabdomyosarcomas (PM‐RMS) are pediatric tumors with a high risk of local failure and severe toxicity. Intensity modulated proton therapy (IMPT) offers improved healthy tissue sparing compared to conventional photon‐based radiotherapy, and proton arc therapy (PAT) might offer further improvement in healthy tissue sparing for these patients, thus emphasizing the need for systematic studies specifically focusing on PM‐RMS patients. Additionally, the relative biological effectiveness (RBE) of protons is known to vary with linear energy transfer (LET). Purpose The aim of this study was to investigate the potential of LET‐optimized PAT for PM‐RMS treatment. Methods Volumetric modulated arc therapy (VMAT) plans, IMPT and PAT plans, both with and without LET optimization were made for 13 PM‐RMS patients using Raystation version 2023B. The plans were evaluated based on the achievement of clinical goals, homogeneity index, delivery time, robustness, LET and variable RBE‐weighted dose within the target and selected OARs. Results LET optimization increased the mean LET in the target from 2.5 keV/µm [2.1, 2.8] to 3.4 keV/µm [2.7, 4.1] for IMPT and from 2.8 keV/µm [2.5, 3.1] to 3.4 keV/µm [2.7, 4.0] for PAT with minor changes in dose distributions. Target coverage and OAR doses were comparable between IMPT and PAT, while both had an expected improvement in OAR sparing compared to VMAT. Delivery times were 134.5 [95.3, 203.7] seconds for the IMPT plans and 197.4 [138.9, 244.6] seconds for the PAT plans before LET optimization, and were for both modalities reduced by around 2–5 seconds after LET optimization. Conclusions The dose distribution was similar across PAT and IMPT in this study, and superior compared to VMAT. LET optimization in the proton plans achieved LET improvements in both target and OARs without compromising dose.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dosimetric comparison of automated noncoplanar volumetric-modulated arc therapy and intensity-modulated proton therapy for total scalp irradiation in angiosarcoma of the scalp.The British journal of radiology · 2026
- Linear energy transfer optimization in proton therapy of sinonasal cancer.Physics and imaging in radiation oncology · 2026
- A phase II randomized study of proton therapy vs intensity-modulated radiation therapy in patients with unilateral head and neck cancer.Journal of the National Cancer Institute · 2026
- Impact of LET‐modifying planning objectives on the optimization of mixed‐modality proton–photon treatmentsMedical Physics · 2026
- Proton arc therapy reduces the dose delivered to circulating blood compared to intensity‐modulated proton therapy for head‐and‐neck cancerJournal of Applied Clinical Medical Physics · 2026
- Can future reirradiation justify upfront proton therapy? An extension of model-based proton therapy selection beyond primary-course NTCP benefitarXiv · 2026